Volmer D A, Lay J O, Billedeau M, Vollmer D L
Food and Drug Administration, National Center for Toxicological Rsearch, Jefferson, AR 72079, USA.
Rapid Commun Mass Spectrom. 1996;10(6):715-20. doi: 10.1002/(SICI)1097-0231(199604)10:6<715::AID-RCM542>3.0.CO;2-K.
Characterization of nitrosation products in cosmetics raw material samples has been accomplished by three liquid chromatography/mass spectrometry (LC/MS) techniques. Two of the techniques involved conventional methodologies of LC/MS and LC/tandem mass spectrometry, both of which can be used to detect and identify products formed under extreme-nitrosation conditions. The third technique utilized an on-line coupling of a photolysis reactor with the LC/MS, and it may be used as a rapid and specific means of screening for the presence of known and unknown N-nitrosamines, which may be carcinogenic.
通过三种液相色谱/质谱(LC/MS)技术完成了对化妆品原料样品中亚硝化产物的表征。其中两种技术涉及LC/MS和LC/串联质谱的传统方法,这两种方法均可用于检测和鉴定在极端亚硝化条件下形成的产物。第三种技术利用光解反应器与LC/MS的在线联用,它可用作快速、特异性地筛查已知和未知N-亚硝胺(可能具有致癌性)是否存在的手段。