Krivickas L S, Nadler S F, Davies M R, Petroski G F, Feinberg J H
Department of Physical Medicine and Rehabilitation, University of Medicine and Dentistry-New Jersey Medical School, Newark, USA.
Am J Phys Med Rehabil. 1996 Jan-Feb;75(1):15-20. doi: 10.1097/00002060-199601000-00005.
Fine wire (FW) intramuscular electrodes and spectral analysis have not previously been used to quantify metabolic muscle fatigue in deep muscles not accessible with surface electrodes. This study compares initial median frequency (IMF) and decline in median frequency with fatigue (SLOPE) using surface and FW electrodes. Eighteen men performed isometric biceps contractions for 100 s. Electromyographic signals were collected using FW and surface electrodes. The recordings of SLOPE was greater with FW (-0.44 v -0.23 %IMF/s) and IMF was higher (195 v 69 Hz). Intrasession reliability for slope was better with FW electrode (intraclass correlation coefficient (ICC) = 0.74; P<0.0001) than with the surface electrode (ICC = 0.43; P = 0.006), but intersession reliability was best with the surface electrode (ICC = 0.50; P = 0.03). Spectral analysis using FW electrodes provides earlier detection of muscle fatigue and can be used in deep muscles, but the reliability must be improved before clinical application.
细钢丝(FW)肌内电极和频谱分析以前尚未用于量化表面电极无法触及的深层肌肉中的代谢性肌肉疲劳。本研究比较了使用表面电极和FW电极时的初始中位频率(IMF)以及中位频率随疲劳的下降情况(SLOPE)。18名男性进行了100秒的等长二头肌收缩。使用FW电极和表面电极收集肌电信号。FW电极记录的SLOPE更大(-0.44对-0.23%IMF/秒),且IMF更高(195对69赫兹)。FW电极测量斜率的组内可靠性优于表面电极(组内相关系数(ICC)=0.74;P<0.0001)(表面电极ICC = 0.43;P = 0.006),但组间可靠性以表面电极最佳(ICC = 0.50;P = 0.03)。使用FW电极进行频谱分析可更早检测到肌肉疲劳,且可用于深层肌肉,但在临床应用前必须提高其可靠性。