Abstract

In vaccinated populations, the diagnosis of measles often requires laboratory confirmation. Serum tested by EIAs has proven sensitive and specific for diagnosing measles. For comparison of detection of measles-specific IgM in oral fluid and serum samples by an antibody-capture EIA, 163 Ethiopian infants who presented for routine measles vaccination were studied. Paired serum and oral fluid samples were collected before and 2 weeks after vaccination; 269 paired samples were adequate for analyses. Of the 104 serum samples that were IgM-positive, 95 (91%) of the paired oral fluid samples were IgM-positive. Of the 165 serum samples that were IgM-negative, 156 (95%) of the paired oral fluid samples were IgM-negative. The Pearson partial correlation coefficient for optical density readings from postvaccination oral fluid compared with serum was 0.81. Oral fluid appears to be an acceptable alternative to serum for measuring measles-specific IgM antibodies by an antibody-capture EIA.

摘要

在已接种疫苗的人群中,麻疹的诊断通常需要实验室确认。酶免疫测定法检测的血清已被证明对诊断麻疹敏感且特异。为了通过抗体捕获酶免疫测定法比较口腔液和血清样本中麻疹特异性IgM的检测情况,对163名前来进行常规麻疹疫苗接种的埃塞俄比亚婴儿进行了研究。在接种疫苗前和接种后2周采集配对的血清和口腔液样本;269对样本可用于分析。在104份IgM阳性的血清样本中,95份(91%)配对的口腔液样本IgM呈阳性。在165份IgM阴性的血清样本中,156份(95%)配对的口腔液样本IgM呈阴性。接种疫苗后口腔液与血清光密度读数的Pearson偏相关系数为0.81。通过抗体捕获酶免疫测定法检测麻疹特异性IgM抗体时,口腔液似乎是血清的一种可接受的替代样本。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验