Suppr超能文献

通过简单的样品制备,利用高效液相色谱法自动测定多胺。

Automated determination of polyamines by high-performance liquid chromatography with simple sample preparation.

作者信息

van Eijk H M, Rooyakkers D R, Deutz N E

机构信息

Department of Surgery, University of Limburg, Maastricht, Netherlands.

出版信息

J Chromatogr A. 1996 Apr 12;730(1-2):115-20. doi: 10.1016/0021-9673(95)01046-7.

Abstract

Recently, a new fully endcapped reversed-phase packing material, Inertsil, was introduced, especially suitable for the determination of basic compounds. We used this packing material to separate ophthaldialdehyde (OPA) derivatives of amino acid derivatives completely from the OPA derivatives of spermine (SPM), spermidine (SPD), putrescine (PUT) and cadaverine (CAD). The obtained separation made the commonly used off-line extraction procedure redundant and thus an on-line sample clean-up was introduced. This enabled automation of the procedure resulting in a better reproducibility and a more efficient use of equipment. Furthermore, no studies are required to determine the extraction recovery. The present method has a cycle time of 30 min. A linear response for each polyamine was found up to 250 pmol, with an R2 ranging from 0.9981 (SPM) to 0.9998 (CAD). The limit of detection, calculated at a signal-to-noise ratio of 3, was 0.1 pmol, corresponding to a plasma concentration of 0.1 mumol/l. The coefficient of variation (C.V.) for the peak area was below 3% and for retention times below 0.5% (n = 15). In order to evaluate the applicability of the method, three different types of sample were chromatographed, e.g. urine (obtained from healthy human volunteers), pig plasma and sulfosalicylic acid homogenates of pig intestine biopsies. Tissue homogenates and urine-specimen could easily be quantitated, while plasma concentrations were just above the limit of detection, resulting in a plasma C.V. ranging from 4.8% (SPM) to 13.6% (SPD) and a tissue C.V. ranging from 2.1% (SPM) to 8.5% (CAD), The urinary C.V.s were not determined. In conclusion, the present method provides an easy way to measure polyamine concentrations for most applications.

摘要

最近,一种新型的全封端反相填充材料Inertsil被推出,它特别适用于碱性化合物的测定。我们使用这种填充材料将氨基酸衍生物的邻苯二甲醛(OPA)衍生物与精胺(SPM)、亚精胺(SPD)、腐胺(PUT)和尸胺(CAD)的OPA衍生物完全分离。所获得的分离结果使得常用的离线萃取程序变得多余,因此引入了在线样品净化。这实现了该程序的自动化,从而获得了更好的重现性并更有效地利用了设备。此外,无需进行研究来确定萃取回收率。本方法的循环时间为30分钟。发现每种多胺在高达250 pmol时呈线性响应,R²范围从0.9981(SPM)到0.9998(CAD)。在信噪比为3时计算得出的检测限为0.1 pmol,相当于血浆浓度为0.1 μmol/l。峰面积的变异系数(C.V.)低于3%,保留时间的变异系数低于0.5%(n = 15)。为了评估该方法的适用性,对三种不同类型的样品进行了色谱分析,例如尿液(取自健康人类志愿者)、猪血浆和猪肠活检组织的磺基水杨酸匀浆。组织匀浆和尿液样本可以很容易地进行定量,而血浆浓度刚好高于检测限,导致血浆C.V.范围从4.8%(SPM)到13.6%(SPD),组织C.V.范围从2.1%(SPM)到8.5%(CAD),未测定尿液的C.V.。总之,本方法为大多数应用提供了一种测量多胺浓度的简便方法。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验