A clinical comparison of Xe-127 and Xe-133 for ventilation studies.

作者信息

Atkins H L, Susskind H, Klopper J F, Ansari A N, Richards P, Fairchild R G

出版信息

J Nucl Med. 1977 Jul;18(7):653-9.

PMID:874143
Abstract

Xenon-133 and xenon-127 were compared by performing ventilation studies with both radionuclides in 19 patients with a variety of lung diseases. Assessment of the counting rate over the chest, relative to the radioactivity in the lungs, permitted the evaluation of each isotope in terms of usable photons detected by a scintillation camera with a large field of view and appropriate collimation. A greater photon yield was obtained with Xe-127. Markedly improved resolution was shown by measurement of a line phantom, but was not apparent on subjective appraisal of scintiphotos except in the washout phase. Xenon-127 appears to be preferable to Xe-133 because of the higher counting rates, lower patient radiation dose, and longer shelf life. In addition, a prior perfusion study using a Tc-99m radiopharmaceutical does not affect the quality of a Xe-127 ventilation study. The use of Xe-127 therefore permits the selection for ventilation studies of only those patients with suspected pulmonary embolism, and eliminates unnecessary radiation exposure. A further improvement in image quality obtained with Xe-127 should be possible with certain modifications of the scintillation camera that would permit use of the 375-keV photopeak along with the 172- and 203-keV gamma energies. Charcoal traps designed for Xe-133 will require additional shielding and longer storage time when used for Xe-127. Xenon-127, however, might be used again after appropriate processing.

摘要

相似文献

1
A clinical comparison of Xe-127 and Xe-133 for ventilation studies.
J Nucl Med. 1977 Jul;18(7):653-9.
2
Nitrogen-13 and xenon-133 ventilation studies.氮-13和氙-133通气研究。
J Nucl Med. 1984 Nov;25(11):1175-82.
3
[Determination of regional ventilation-perfusion ratio with xenon-133].[用氙 - 133测定局部通气 - 灌注比]
Nucl Med (Stuttg). 1975 Aug 31;14(3):232-9.
4
[133Xe functional evaluation of the lung in obstructive syndromes (author's transl)].
Radiol Med. 1976 Dec;62(12):953-64.
5
Dynamic measurement of regional ventilation and perfusion of the lung with Xe-133.用Xe-133对肺区域通气和灌注进行动态测量。
J Nucl Med. 1977 Jul;18(7):660-8.
6
Initial assessment of a simple functional image of ventilation.通气简单功能图像的初步评估。
J Nucl Med. 1976 Feb;17(02):88-92.
7
A comparison of xenon-133 and xenon-127 for the determination of regional cerebral blood flow measured by dynamic SPECT.
Psychiatry Res. 1992 Nov;45(3):187-200.
8
Clinical efficacy of a large-field-of-view scintillation camera.
J Nucl Med. 1975 Dec;16(12):1158-65.
9
[ 133 Xe- 99m Tc-MAP in lung scintigraphy].
Schweiz Med Wochenschr. 1973 Jun 16;103(24):857-63 contd.
10
[Regional distribution of ventilation, perfusion and ventilation/perfusion ratio in seated healthy men, chronic bronchitic and emphysematous patients (author's transl)].
Bull Physiopathol Respir (Nancy). 1974 Nov-Dec;10(6):811-30.

引用本文的文献

1
Assessment of pulmonary ventilation scans using xenon-127 in the diagnosis of pulmonary embolism.
Eur J Nucl Med. 1984;9(4):154-6. doi: 10.1007/BF00251462.
2
Computer processing of perfusion, ventilation, and V/Q images to highlight pulmonary embolism.对灌注、通气和V/Q图像进行计算机处理以突出显示肺栓塞。
Eur J Nucl Med. 1981;6(7):309-15. doi: 10.1007/BF00262525.