Transport in lymphatic capillaries. II. Microscopic velocity measurement with fluorescence photobleaching.

作者信息

Berk D A, Swartz M A, Leu A J, Jain R K

机构信息

Edwin L. Steele Laboratory, Department of Radiation Oncology, Massachuseits General Hospital, Boston, USA.

出版信息

Am J Physiol. 1996 Jan;270(1 Pt 2):H330-7. doi: 10.1152/ajpheart.1996.270.1.H330.

Abstract

Despite its relevance to the physiology of lymph formation and propulsion, the instantaneous flow velocity in single lymphatic capillaries has not been measured to date. The method of fluorescence recovery after photobleaching (FRAP) was adapted for this purpose and used to characterize flow in the lymphatic capillaries in tail skin of anesthetized mice during a constant-pressure intradermal injection of fluorescein isothiocyanate-dextran (mol wt 2 x 10(6). The median lymph flow velocity was 4.7 microns/s, and the velocity magnitude ranged from 0 to 29 microns/s. The direction of flow was generally proximal, but stasis and backflow toward the site of injection was also detected. Evidence for oscillatory flow was detected in some FRAP experiments, and in separate experiments a periodicity of approximately 120 min-1, directly correlated to respiration frequency, was measured by tracking the motion of fluorescent latex microspheres (1 micron diam) introduced into the lymphatic capillary network. The velocity magnitude showed a correlation with duration of infusion but not with distance from injection site. It is speculated that the temporal decay of mean velocity magnitude could be related to the relaxation of local pressure gradients as partially collapsed vessels expand during the infusion.

摘要

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验