Suppr超能文献

两个欧洲人群中多频阻抗与身体水分分布关系的比较研究。

Comparative study of the relationship between multi-frequency impedence and body water compartments in two European populations.

作者信息

Tagliabue A, Cena H, Deurenberg P

机构信息

Department of Human Nutrition, University of Pavia, Italy.

出版信息

Br J Nutr. 1996 Jan;75(1):11-19. doi: 10.1079/bjn19960106.

Abstract

To investigate possible differences in the relationship between multi-frequency impedance and body-water compartments (total body water (TBW) and extracellular water (ECW)) measured by dilution techniques in two European populations, we studied forty Italian (twenty male and twenty female) and forty-three Dutch (twenty-three male and twenty female) healthy subjects aged 19-41 years. The main differences in body build between the two groups were height, trunk length and the two ratios TBW/height and ECW/height. Population-specific prediction formulas for ECW (at 1 kHz) and TBW (at 100 kHz) were developed. The prediction errors for ECW and TBW were about 0.6 and 1.5 kg respectively, (CV 4%) in both groups. Cross-validation analysis showed no significant error in the prediction of TBW but a slight error (range -4.9 to +2.8%) in the ECW prediction. The biases in both TBW and ECW were correlated with ECW/TBW (r -0.44, P < 0.0005 and r +0.52, P < 0.0005 respectively) in the two groups; the biases in ECW were also related to ECW/height (r 0.51, P < 0.001), TBW/height (r 0.25, P < 0.05), trunk length (r 0.36, P < 0.001) and Z1/Z100 (r 0.32, P < 0.01). In conclusion, the water distribution between the extra- and intracellular compartments emerged in the present study as the major cause of error in the prediction of body water, and in particular of ECW from impedance measurements with a population-specific equation. Moreover, body build, expressed as TBW/height and ECW/height, had an impact on the bias.

摘要

为研究两个欧洲人群中通过稀释技术测量的多频阻抗与身体水分 compartments(总体水(TBW)和细胞外水(ECW))之间关系的可能差异,我们研究了40名意大利人(20名男性和20名女性)和43名荷兰人(23名男性和20名女性),年龄在19至41岁之间的健康受试者。两组身体结构的主要差异在于身高、躯干长度以及两个比率TBW/身高和ECW/身高。开发了针对ECW(1kHz时)和TBW(100kHz时)的特定人群预测公式。两组中ECW和TBW的预测误差分别约为0.6kg和1.5kg(CV 4%)。交叉验证分析表明,TBW预测无显著误差,但ECW预测存在轻微误差(范围为-4.9%至+2.8%)。两组中TBW和ECW的偏差均与ECW/TBW相关(r分别为-0.44,P < 0.0005和r为+0.52,P < 0.0005);ECW的偏差还与ECW/身高(r为0.51,P < 0.001)、TBW/身高(r为0.25,P < 0.05)、躯干长度(r为0.36,P < 0.001)和Z1/Z100(r为0.32,P < 0.01)有关。总之,在本研究中,细胞外和细胞内 compartments 之间的水分分布是预测身体水分尤其是使用特定人群方程通过阻抗测量预测ECW时误差的主要原因。此外,以TBW/身高和ECW/身高表示的身体结构对偏差有影响。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验