Endotoxin-induced changes in intrarenal pO2, measured by in vivo electron paramagnetic resonance oximetry and magnetic resonance imaging.

作者信息

James P E, Bacic G, Grinberg O Y, Goda F, Dunn J F, Jackson S K, Swartz H M

机构信息

EPR Center, Dartmouth Medical School, Hanover, NH 03755-3863, USA.

出版信息

Free Radic Biol Med. 1996;21(1):25-34. doi: 10.1016/0891-5849(95)02221-x.

Abstract

Electron Paramagnetic Resonance (EPR) oximetry was used to measure tissue oxygen tension (pO2-partial pressure of oxygen) simultaneously in the kidney cortex and outer medulla in vivo in mice. pO2 in the cortex region was higher compared to that in the outer medulla. An intravenous injection of endotoxin resulted in a sharp drop in pO2 in the cortex and an increase in the medulla region, resulting in a transient period of equal pO2 in both regions. In control kidneys, functional Magnetic Resonance (MR) images showed the cortex region to have high signal intensity (T2*-weighted images), indicating that this region was well supplied with oxygenated hemoglobin, whereas the outer medulla showed low signal intensity. After administration of endotoxin, we observed an immediate increase in signal intensity in the outer medulla region, reflecting an increased level of oxygenated blood in this region. Pretreatment of mice with NG-monomethyl-L-arginine prevented both the changes in tissue pO2 and distribution of oxygenated hemoglobin, suggesting that localized production of nitric oxide has a critical role to play in renal medullary hemodynamics. In combining in vivo EPR with MR images of kidneys, we demonstrate the usefulness of these techniques for monitoring renal pO2 and changes in the distribution of oxygen.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验