Baay M F, Quint W G, Koudstaal J, Hollema H, Duk J M, Burger M P, Stolz E, Herbrink P
Department of Dermatovenereology, Erasmus University, University Hospital, Rotterdam, The Netherlands.
J Clin Microbiol. 1996 Mar;34(3):745-7. doi: 10.1128/jcm.34.3.745-747.1996.
We have compared the efficacies of three general primer pairs for the detection of human papillomavirus (HPV) DNA in formaldehyde-fixed paraffin-embedded carcinomas. The use of these primer pairs leads to underestimates of the HPV prevalence (GP5/6, 61.1%; CPI/IIG, 57.4%; MY09/11, 46.9%; combined, 72.8%). The efficacy of each primer pair seemed to be inversely correlated to the length of the amplimer produced. By using newly developed type-specific primer pairs (amplimer length, approximately 100 bp), an increase in HPV DNA detection (87.6%) was found.