Suppr超能文献

铊-201、锝-99m-司他比、锝-99m-替曲膦和锝-99m-呋罗膦平面及单光子发射计算机断层扫描(SPECT)正常数据文件的定量比较

Quantitative comparison of planar and SPECT normal data files of thallium-201, technetium-99m-sestamibi, technetium-99m-tetrofosmin and technetium-99m-furifosmin.

作者信息

Naruse H, Daher E, Sinusas A, Jain D, Natale D, Mattera J, Makuch R, Wackers F J

机构信息

Department of Diagnostic Radiology, Yale University School of Medicine, New Haven, Conneticut 06520-8042, USA.

出版信息

J Nucl Med. 1996 Nov;37(11):1783-8.

PMID:8917175
Abstract

UNLABELLED

In recent years, several of 99mTc-labeled myocardial perfusion imaging agents have been developed, such as 99mTc-sestamibi, 99mTc-tetrofosmin and 99mTc-furifosmin. Although images obtained with these new tracers have a general similar appearance, there are differences in the myocardial kinetics, body distribution, general quality of images and imaging protocols. The aim of this study was to quantitatively compare normal exercise planar and SPECT data files obtained with 201TI and 99mTc-labeled agents.

METHODS

Lower-limit-of-normal curves were generated for each specific radiopharmaceutical from normal subjects with low (< 3%) pretest likelihood of coronary artery disease using circumferential count distribution profiles from planar and SPECT exercise images. Lower-limit-of-normal curves were statistically compared using the nonparametric Kruskall-Wallis and Wilcoxon tests.

RESULTS

Planar and SPECT lower-limit-of-normal curves generated for each radiopharmaceutical showed general similarities. Statistically significant differences among the lower-limit-of-normal curves were found in the planar left anterior oblique view and in the planar left lateral view (p < 0.05 for each). No statistically significant differences existed between lower-limit-of-normal curves of various radiopharmaceuticals on the planar anterior view and on SPECT imaging.

CONCLUSION

For quantitative analysis of planar images, radiopharmaceutical-specific normal data files are mandatory. Although SPECT normal data files of various radiopharmaceuticals are not statistically different, they are not identical. It appears, nevertheless, prudent to use radiopharmaceutical-specific normal data files for quantitative analysis of SPECT images.

摘要

未标注

近年来,已研发出几种99mTc标记的心肌灌注显像剂,如99mTc- sestamibi、99mTc-替曲膦和99mTc-呋罗膦。尽管用这些新示踪剂获得的图像总体外观相似,但在心肌动力学、体内分布、图像总体质量和成像方案方面存在差异。本研究的目的是定量比较用201Tl和99mTc标记的试剂获得的正常运动平面和SPECT数据文件。

方法

使用平面和SPECT运动图像的圆周计数分布曲线,从冠状动脉疾病预测试验可能性低(<3%)的正常受试者中为每种特定放射性药物生成正常下限曲线。使用非参数Kruskal-Wallis和Wilcoxon检验对正常下限曲线进行统计学比较。

结果

为每种放射性药物生成的平面和SPECT正常下限曲线显示出总体相似性。在平面左前斜位视图和平面左侧视图中,正常下限曲线之间存在统计学显著差异(每种情况p<0.05)。在平面前视图和SPECT成像上,各种放射性药物的正常下限曲线之间不存在统计学显著差异。

结论

对于平面图像的定量分析,特定放射性药物的正常数据文件是必需的。尽管各种放射性药物的SPECT正常数据文件在统计学上没有差异,但它们并不相同。然而,对于SPECT图像的定量分析,使用特定放射性药物的正常数据文件似乎是谨慎的做法。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验