Suppr超能文献

[使用99mTc-ECD放射性核素血管造影术、单光子发射计算机断层扫描(SPECT)和单点动脉采样对脑血流量进行定量测量]

[Quantitative measurements of cerebral blood flow using 99mTc-ECD radionuclide angiography, SPECT and one-point arterial sampling].

作者信息

Isaka Y, Yoshikawa T, Narita M, Ashida K, Imaizumi M, Harada M

机构信息

Department of Internal Medicine, Osaka National Hospital.

出版信息

Kaku Igaku. 1996 Sep;33(9):965-73.

PMID:8921664
Abstract

We quantified regional cerebral blood flow using 99mTc-bicisate ethyl cysteinate dimer (ECD) radionuclide (RN) angiography, one-point arterial sampling and static SPECT in 12 patients. The tracer was injected as a bolus into the right antecubital vein, and time-activity curves over the cerebrum and the aortic arch were sequentially recorded for 300 s with 3 s intervals in a 128 x 128 format with a large-field of view gamma camera equipped with a low-energy collimator. Blood was obtained from the femoral artery immediately after stopping the RN angiography and the arterial concentration of 99mTc-ECD was calculated. Thereafter, the SPECT data acquisition was started with the subject's head immobilized. We applied a three-compartment kinetic model: The influx constant of 99mTc-ECD from blood to brain (K1) and the transfer of ECD from diffusible compartment to nondiffusible one in the blood (k5). The K1 value was compared with the global cerebral blood flow value (Fa) measured by the 133Xe clearance technique. From the kinetic analysis, the following parameter values could be calculated: K1 = 0.21 +/- 0.05 (ml/ml/min), k5 = 0.66 +/- 0.15 (/min), Fa = 0.32 +/- 0.09 (ml/ml/min) and the extraction fraction E = K1/Fa = 0.65 +/- 0.05. There was a strong correlation between K1 and Fa (Y = 0.53X + 3.7; rs = 0.91). By combining the K1 and E values in the whole-brain, we can obtain the absolute global flow value and regional 99mTc-ECD CBF maps if the average concentration of the tracer in the whole-brain is used as a reference. Our method is less invasive and suitable for quantitation of cerebral blood flow in patients with brain disorders.

摘要

我们采用99mTc-双半胱乙酯(ECD)放射性核素(RN)血管造影、单点动脉采样和静态单光子发射计算机断层扫描(SPECT)对12例患者的局部脑血流量进行了定量分析。将示踪剂以团注方式注入右肘前静脉,使用配备低能准直器的大视野γ相机,以128×128格式、3秒间隔连续记录大脑和主动脉弓上的时间-活性曲线300秒。在停止RN血管造影后立即从股动脉取血,计算99mTc-ECD的动脉浓度。此后,在受试者头部固定的情况下开始SPECT数据采集。我们应用三室动力学模型:99mTc-ECD从血液到脑的流入常数(K1)以及ECD在血液中从可扩散室向不可扩散室的转移(k5)。将K1值与通过133Xe清除技术测得的全脑血流量值(Fa)进行比较。通过动力学分析,可以计算出以下参数值:K1 = 0.21±0.05(ml/ml/min),k5 = 0.66±0.15(/min),Fa = 0.32±0.09(ml/ml/min),提取分数E = K1/Fa = 0.65±0.05。K1与Fa之间存在很强的相关性(Y = 0.53X + 3.7;rs = 0.91)。如果将示踪剂在全脑中的平均浓度用作参考,通过结合全脑的K1和E值,我们可以获得绝对全脑血流量值和局部99mTc-ECD脑血流量图。我们的方法侵入性较小,适用于脑部疾病患者的脑血流量定量分析。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验