Suppr超能文献

锝-99m 锡胶体标记白细胞闪烁扫描术在疼痛性关节置换术评估中的应用

Tc-99m stannous colloid-labeled leukocyte scintigraphy in the evaluation of the painful arthroplasty.

作者信息

Chik K K, Magee M A, Bruce W J, Higgs R J, Thomas M G, Allman K C, Van der Wall H

机构信息

Department of Nuclear Medicine, Concord Hospital, Sydney, Australia.

出版信息

Clin Nucl Med. 1996 Nov;21(11):838-43. doi: 10.1097/00003072-199611000-00003.

Abstract

The aim of this study was to evaluate the utility of scintigraphy using leukocytes labeled with Tc-99m stannous colloid in the assessment of painful arthroplasties. The results of three-phase bone scintigraphy and imaging with Tc-99m-labeled leukocytes in 40 patients with painful joint prostheses, requiring the exclusion of infection are reported. Results were compared with microbiologic culture and/or long-term clinical review. Bone scintigraphy had a sensitivity of 100%, a specificity of 64%, and a diagnostic accuracy of 73% in detecting prosthetic infection. Tc-99m-labeled leukocytes yielded a sensitivity of 70%, a specificity of 100%, and a diagnostic accuracy of 93%. Leukocyte scintigraphy improves the specificity of bone scintigraphy in the assessment of the painful prosthetic joint. A positive study is highly suggestive of infection and warrants appropriate treatment.

摘要

本研究的目的是评估使用锝-99m 胶体标记白细胞的闪烁扫描术在评估疼痛性关节置换术中的效用。报告了 40 例需要排除感染的疼痛性关节假体患者的三相骨闪烁扫描和锝-99m 标记白细胞成像的结果。将结果与微生物培养和/或长期临床复查进行比较。骨闪烁扫描在检测假体感染方面的敏感性为 100%,特异性为 64%,诊断准确性为 73%。锝-99m 标记白细胞的敏感性为 70%,特异性为 100%,诊断准确性为 93%。白细胞闪烁扫描术提高了骨闪烁扫描术在评估疼痛性假体关节中的特异性。阳性检查结果高度提示感染,需要进行适当治疗。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验