Suppr超能文献

Model clamp and its application to synchronization of rabbit sinoatrial node cells.

作者信息

Wilders R, Verheijck E E, Kumar R, Goolsby W N, van Ginneken A C, Joyner R W, Jongsma H J

机构信息

Department of Medical Physiology and Sports Medicine, Utrecht University, The Netherlands.

出版信息

Am J Physiol. 1996 Nov;271(5 Pt 2):H2168-82. doi: 10.1152/ajpheart.1996.271.5.H2168.

Abstract

A method for coupling an isolated cardiac cell to a simulated cardiac cell, i.e., the real-time solution of a mathematical model of such cell, has been developed. With this "model clamp" technique, the real cell and the model cell are coupled by any desired value of intercellular coupling conductance, producing the effect of mutual interaction by electrical coupling through gap junctional channels. We implemented the model clamp technique with our previously published model of an isolated rabbit sinoatrial node cell. We used this model clamp system to study synchronization of sinoatrial node cells with regard to the critical value of intercellular coupling conductance required for frequency entrainment and the common interbeat interval during frequency entrainment. This common interbeat interval lay between the intrinsic intervals of the real cell and the model cell, but was closer to that of the intrinsically faster beating cell. Critical coupling conductance increased with increasing difference in intrinsic interbeat interval of the real cell and the model cell and ranged between 50 and 300 pS in 11 hybrid cell pairs.