Left ventricular (LV) volume (V) is an essential parameter for assessment of the cardiac pump function. Measurement of LVV in situ by a conductance catheter method has been widely used in dogs and humans but not yet in small experimental animals such as rats. We instituted a miniaturized six-electrode conductance catheter (3-F) for rat LVV measurement and its signal processing apparatus. We compared stroke volumes (SVs) simultaneously measured with this conductance catheter introduced into the LV through the apex and an electromagnetic flow probe placed on the ascending aorta during gradual decreases in LVV by an inferior vena caval occlusion. A high and linear correlation (r = 0.982) was obtained between these differently measured by SVs pooled from six rats. In another group of three rats, LV pressure was simultaneously measured with a 3-F catheter-tip micromanometer introduced into the LV through the apex. We obtained the slope of the end-systolic pressure-volume (P-V) relationship (Emax) by a gradual ascending aortic occlusion. After administration of propranolol, Emax obviously decreased with no change in volume intercept of the P-V relationship. The conductance volumetry proved to be useful in rats.