Van Os E C, McKinney J A, Zins B J, Mays D C, Schriver Z H, Sandborn W J, Lipsky J J
Department of Medicine, Mayo Clinic/Mayo Foundation, Rochester, MN 59905, USA.
J Chromatogr B Biomed Appl. 1996 Apr 26;679(1-2):147-54. doi: 10.1016/0378-4347(96)00007-2.
A specific, sensitive, single-step solid-phase extraction and reversed-phase high-performance liquid chromatographic method for the simultaneous determination of plasma 6-mercaptopurine and azathioprine concentrations is reported. Following solid-phase extraction, analytes are separated on a C18 column with mobile phase consisting of 0.8% acetonitrile in 1 mM triethylamine, pH 3.2, run on a gradient system. Quantitation limits were 5 ng/ml and 2 ng/ml for azathioprine and 6-mercaptopurine, respectively. Peak heights correlated linearly to known extracted standards for 6-mercaptopurine and azathioprine (r = 0.999) over a range of 2-200 ng/ml. No chromatographic interferences were detected.