Koch G, Gutschi S, Pascher O, Fruhwirth J, Hauser H
Klinische Abteilung für Gefsschirurgie, Universitätsklinik für Chirurgie Graz.
Zentralbl Chir. 1996;121(9):761-7.
In an eight year-period from 1988 to 1995 653 femoropopliteal and femorocrural bypasses were performed. 347 above-knee reconstructions 206 below-knee reconstructions and at last 100 femorocrural bypasses were analysed. The cumulative patency rate after a follow up of three years for above-knee vein bypasses was 90%, patency rate for PTFE grafts in the same period was 52%, for ovine collagen grafts 56%. For below-knee bypasses with autologous saphenous vein a function rate of 76% could be observed in the same period, the rate of PTFE grafts in this position was only 30%. In this position 3-year patency rates of 50% were achieved with ovine collagen grafts. This difference was statistically significant. Three years cumulative patency rate for femorocrural reconstructions with greater saphenous vein was 72%, the function rate for PTFE in this position was below 30% after a follow up of one year, with ovine grafts below 40%. Graft infection, aneurysm formation and postoperative mortality were low in all groups. Our data demonstrate, that patency rates of autologous vein bypasses could not be achieved with PTFE or ovine collagen prosthesis in any femoropopliteal the femorocrural position. We therefore cannot confirm the recommendation to use alloplastic grafts as primary choice for above knee bypasses to spare the saphenous vein.
在1988年至1995年的八年期间,共进行了653例股腘和股胫旁路手术。对347例膝上重建、206例膝下重建以及最后100例股胫旁路手术进行了分析。膝上静脉旁路术后三年的累积通畅率为90%,同期聚四氟乙烯(PTFE)移植物的通畅率为52%,羊胶原移植物的通畅率为56%。对于自体大隐静脉膝下旁路手术,同期功能率为76%,该部位PTFE移植物的功能率仅为30%。在该部位,羊胶原移植物的三年通畅率达到50%。这种差异具有统计学意义。大隐静脉股胫重建的三年累积通畅率为72%,该部位PTFE移植物在随访一年后的功能率低于30%,羊移植物低于40%。所有组的移植物感染、动脉瘤形成和术后死亡率均较低。我们的数据表明,在任何股腘或股胫部位,PTFE或羊胶原假体均无法达到自体静脉旁路的通畅率。因此,我们不能确认将异种移植物作为膝上旁路手术的首选以保留大隐静脉的建议。