Suppr超能文献

用于传统巩膜扣带术的改良视网膜下液针吸引流术。

Modified needle drainage of subretinal fluid for conventional scleral buckling procedures.

作者信息

Azad R V, Talwar D, Pai A

机构信息

Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi.

出版信息

Ophthalmic Surg Lasers. 1997 Feb;28(2):165-7.

PMID:9054492
Abstract

This study evaluated the efficacy and safety of a new technique used to drain subretinal fluid (SRF) during conventional scleral buckling procedures. The procedure was performed on 15 patients with primary rhegmatogenous retinal detachment in whom drainage of SRF was necessary during the surgery. It was successful in all but 1 case. The only significant complication was subretinal hemorrhage from the punctured choroid in 1 case, which resolved spontaneously without subsequent complications. This technique reduced the risk of complications during external SRF drainage, especially retinal and vitreous incarceration.

摘要

本研究评估了一种在传统巩膜扣带手术中用于引流视网膜下液(SRF)的新技术的疗效和安全性。该手术针对15例原发性孔源性视网膜脱离患者进行,这些患者在手术过程中需要引流SRF。除1例患者外,其余均成功。唯一的严重并发症是1例因穿刺脉络膜导致的视网膜下出血,该出血自行消退,未出现后续并发症。该技术降低了外部引流SRF过程中的并发症风险,尤其是视网膜和玻璃体嵌顿的风险。