• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Estimation of fluid absorption by using the area under the curve for ethanol in expired air.

作者信息

Hahn R G

机构信息

Department of Anaesthesia, Stockholm South Hospital, Sweden.

出版信息

Urol Int. 1997;58(1):25-9. doi: 10.1159/000282940.

DOI:10.1159/000282940
PMID:9058516
Abstract

The use of irrigating fluid containing a small amount of ethanol allows fluid absorption to be monitored by means of expired-breath tests during transurethral resection of the prostate (TURP). There is, however, no consensus concerning how the breath ethanol data should be converted into the volume of irrigant absorbed. The present study examines the use of the product of concentration and time (area under the curve) to predict how much fluid is absorbed. Intermittent infusions of ethanol in 5 volunteers showed that the relationship between area under the curve and ethanol load was best described by a polynomial expression. This was also applicable to the uptake of small volumes of irrigating fluid during 16 TURPs. When patients with large-sized absorption (> 1,000 ml) were also considered, however, the precision was better when the absorbed volume was predicted by a multiple linear regression formula where the ethanol level in the exhaled breath at the end of any 10-min period during TURP and the time during which ethanol had been detected served as independent factors.

摘要

相似文献

1
Estimation of fluid absorption by using the area under the curve for ethanol in expired air.
Urol Int. 1997;58(1):25-9. doi: 10.1159/000282940.
2
Calculation of irrigant absorption by measurement of breath alcohol level during transurethral resection of the prostate.
Br J Urol. 1991 Oct;68(4):390-3. doi: 10.1111/j.1464-410x.1991.tb15358.x.
3
Expired breath ethanol measurement to calculate irrigating fluid absorption during transurethral resection of the prostate: experience in a district general hospital.
Br J Urol. 1996 Feb;77(2):198-202. doi: 10.1046/j.1464-410x.1996.08866.x.
4
Validation of the ethanol breath test and on-table weighing to measure irrigating fluid absorption during transurethral prostatectomy.经尿道前列腺切除术期间用于测量冲洗液吸收的乙醇呼气试验和术中称重法的验证
BJU Int. 2002 Dec;90(9):872-5. doi: 10.1046/j.1464-410x.2002.03038.x.
5
Ethanol monitoring of irrigating fluid absorption in transurethral prostatic surgery.
Anesthesiology. 1988 Jun;68(6):867-73. doi: 10.1097/00000542-198806000-00006.
6
No evidence of fluid absorption during continuous low-pressure transurethral resection of the prostate: assessment by measuring expiratory breath ethanol concentrations.经尿道前列腺连续低压切除术期间无液体吸收证据:通过测量呼气乙醇浓度进行评估
Eur Urol. 1999 Aug;36(2):103-6. doi: 10.1159/000067979.
7
Ethanol monitoring of transurethral prostatic resection during inhaled anesthesia.
Anesth Analg. 1992 Dec;75(6):983-8. doi: 10.1213/00000539-199212000-00018.
8
Blood ammonia concentrations resulting from absorption of irrigating fluid containing glycine and ethanol during transurethral resection of the prostate.经尿道前列腺切除术中吸收含甘氨酸和乙醇的冲洗液导致的血氨浓度
Scand J Urol Nephrol. 1991;25(2):115-9. doi: 10.3109/00365599109024544.
9
[Calculation of lavage volume in transurethral prostate resection (TURP)].[经尿道前列腺切除术(TURP)中灌洗量的计算]
Anasthesiol Intensivmed Notfallmed Schmerzther. 1997 Apr;32(4):219-25. doi: 10.1055/s-2007-995041.
10
Early detection of the TUR syndrome by marking the irrigating fluid with 1% ethanol.通过用1%乙醇标记冲洗液来早期检测经尿道前列腺电切综合征。
Acta Anaesthesiol Scand. 1989 Feb;33(2):146-51. doi: 10.1111/j.1399-6576.1989.tb02878.x.