Lundqvist S, Hietala S O, Groth S, Sjödin J G
Department of Diagnostic Radiology, University Hospital, Umeå, Sweden.
Acta Radiol. 1997 Jan;38(1):68-72. doi: 10.1080/02841859709171244.
To derive new formulae for the calculation of single sample clearance of the contrast medium iohexol and to compare the formulae to a selection of existing single sample clearance formulae derived for the calculation of 51Cr-EDTA and 99mTc-DTPA clearance.
Glomerular filtration rate (GFR) was calculated from total plasma clearance of iohexol used for urography in 902 patients. Two plasma samples were drawn in each patient. Automated x-ray fluorescence analysis equipment was used for the plasma iodine analysis. Single and multiple sample iohexol clearance values were compared. In 77 patients the multiple sample clearance values were additionally compared to a 51Cr-EDTA clearance performed simultaneously or within 14 days.
The precision of the results calculated by the existing single sample clearance formulae and the derived iohexol single sample clearance formulae were essentially the same. The most precise of the derived formulae was that based on the Bak Christensen & Groth formula. The correlation between multiple sample clearance of iohexol and 51Cr-EDTA was high (r = 0.918).
Iohexol can substitute 51Cr-EDTA for GFR measurement. A valid GFR can be calculated from a single plasma sample determination of iohexol clearance using either the existing formulae or the new formulae derived from the present study.
推导用于计算造影剂碘海醇单样本清除率的新公式,并将这些公式与为计算51Cr-乙二胺四乙酸(51Cr-EDTA)和99m锝-二乙三胺五乙酸(99mTc-DTPA)清除率而推导的一系列现有单样本清除率公式进行比较。
根据902例患者用于尿路造影的碘海醇总血浆清除率计算肾小球滤过率(GFR)。每位患者采集两份血浆样本。使用自动X射线荧光分析设备进行血浆碘分析。比较碘海醇单样本和多样本清除率值。在77例患者中,还将多样本清除率值与同时或在14天内进行的51Cr-EDTA清除率进行比较。
现有单样本清除率公式和推导的碘海醇单样本清除率公式计算结果的精度基本相同。推导公式中最精确的是基于巴克·克里斯蒂安森和格罗思公式的那个。碘海醇多样本清除率与51Cr-EDTA之间的相关性很高(r = 0.918)。
碘海醇可替代51Cr-EDTA用于GFR测量。使用现有公式或本研究推导的新公式,通过单次血浆样本测定碘海醇清除率即可计算出有效的GFR。