Baczkowska T, Rell K, Matuszewicz D, Paczek L, Gaciong Z
Instytut Transplantologii Akademii Medycznej w Warszawie.
Pol Arch Med Wewn. 1997 Jul;98(7):3-7.
X-ray fluorescence analysis provides a simple method of measuring glomerular filtration rate from the clearance unlabeled radiographic contrast media. To measure the accuracy iopromide clearance using a clinically simple 2-sample single injection technique, a comparison was made in 29 patients with 51Cr-EDTA clearance. The clearance of iopromide and 51Cr-EDTA were virtually identical (r = 0.967) and no side effects of the procedure were noted. Iopromide clearance using X-ray fluorescence is simple, rapid, safe and accurate method to determine glomerular filtration rate for research and clinical purposes.
X射线荧光分析提供了一种通过未标记的放射造影剂清除率来测量肾小球滤过率的简单方法。为了使用临床简单的双样本单次注射技术测量碘普罗胺清除率的准确性,对29例患者的碘普罗胺清除率与51Cr-EDTA清除率进行了比较。碘普罗胺和51Cr-EDTA的清除率几乎相同(r = 0.967),且未观察到该操作的副作用。使用X射线荧光法测定碘普罗胺清除率是一种简单、快速、安全且准确的方法,可用于研究和临床目的来测定肾小球滤过率。