This prospective study was designed to assess the diagnostic sensitivity, specificity and negative predictive value of the NycoCard D-dimer plasma immunofiltration assay in patients with suspected deep vein thrombosis (DVT) confirmed by ultrasonography/venography. 84 medical patients were recruited: 43 patients (51%) had proven venous thrombosis, 33 by venography and 10 by ultrasonography. The sensitivity of NycoCard D-dimer in patients with DVT was 95.3%, the specificity was 22.0% and the negative predictive value was 81.8%. An algorithm including the NycoCard D-dimer test for the acute management of DVT is proposed. This would enable low-risk patients to be discharged early from hospital, without imaging or anticoagulant therapy.
本前瞻性研究旨在评估NycoCard D - 二聚体血浆免疫过滤测定法对经超声检查/静脉造影证实的疑似深静脉血栓形成(DVT)患者的诊断敏感性、特异性和阴性预测值。招募了84名内科患者:43名患者(51%)经证实有静脉血栓形成,其中33名通过静脉造影证实,10名通过超声检查证实。NycoCard D - 二聚体对DVT患者的敏感性为95.3%,特异性为22.0%,阴性预测值为81.8%。提出了一种包括NycoCard D - 二聚体检测用于DVT急性处理的算法。这将使低风险患者能够早期出院,无需影像学检查或抗凝治疗。