A novel screening procedure for the sulfate and glucuronide conjugates of testosterone (T) and epitestosterone (E) in human urine was developed based on liquid-solid extraction and microbore high-performance liquid chromatography combined on-line with ion-spray tandem mass spectrometry. Confirmation of the sulfate and glucuronide conjugates of testosterone and epitestosterone isolated from normal human urine was achieved by selected reaction monitoring of characteristic product ions of the parent compounds. Endogenous levels of the steroid conjugates are detected in normal male urine and an increase is observed when the sample is fortified with authentic analytical standards of the conjugates. Calibration curves of all steroid conjugates in urine are linear over a range of twenty. Deuterated internal standards of testosterone glucuronide and epitestosterone sulfate were used for quantitation of the endogenous conjugates. T/E ratios were determined based on the glucuronide fractions of six replicates from a normal male and were shown to be statistically reproducible and below the accepted T/E threshold of 6:1. Sulfate conjugates were shown to be present at significantly lower levels in the urine. The method has potential as an alternative for monitoring anabolic steroid conjugates in human urine.
基于液固萃取和微径高效液相色谱与离子喷雾串联质谱联用技术,开发了一种用于检测人尿中睾酮(T)和表睾酮(E)的硫酸盐和葡萄糖醛酸酯结合物的新型筛查方法。通过对母体化合物特征产物离子的选择反应监测,对从正常人尿中分离出的睾酮和表睾酮的硫酸盐和葡萄糖醛酸酯结合物进行了确认。在正常男性尿液中检测到类固醇结合物的内源性水平,当样品用结合物的真实分析标准品强化时,观察到水平升高。尿液中所有类固醇结合物的校准曲线在20的范围内呈线性。使用睾酮葡萄糖醛酸酯和表睾酮硫酸盐的氘代内标物对内源性结合物进行定量。基于一名正常男性六次重复样本的葡萄糖醛酸酯部分测定了T/E比值,结果显示具有统计学可重复性且低于公认的6:1的T/E阈值。硫酸盐结合物在尿液中的含量明显较低。该方法有潜力作为监测人尿中合成代谢类固醇结合物的替代方法。