Melhem E R, Guidone P L, Jara H, Yucel E K
Department of Radiology, Boston University Medical Center, MA 02118, USA.
AJR Am J Roentgenol. 1997 Apr;168(4):1091-5. doi: 10.2214/ajr.168.4.9124121.
The purpose of this study was to evaluate the ability of T1-weighted fast spin-echo MR sequences to provide improved contrast-to-noise ratios for contrast-enhanced lesions during acquisition times shorter than those used for conventional T1-weighted spin-echo MR sequences.
We compared contrast-to-noise ratios of 32 enhancing brain lesions in 25 patients on T1-weighted spin-echo (546/10 [TR/TE]; two excitations; acquisition time, 4 min 12 sec) and on fast spin-echo (546/10 [TR/effective TE]; echo-train length, 4; echo spacing, 10 msec; two excitations; acquisition time, 1 min 45 sec) MR images obtained at 1.5 T after i.v. administration of 0.10 mmol/kg gadopentetate dimeglumine.
The contrast-enhanced T1-weighted fast spin-echo MR images showed approximately a 12% reduction in the signal-to-noise ratios of the background white matter without an accompanying reduction in the signal-to-noise ratios of the enhancing lesions or CSF when compared with the contrast-enhanced T1-weighted spin-echo MR images. The contrast-enhanced T1-weighted fast spin-echo MR images provided a 23% improvement in the contrast-to-noise ratios of enhancing lesions over the contrast-enhanced T1-weighted spin-echo images (p < .001).
Contrast-enhanced T1-weighted fast spin-echo MR imaging showed a statistically significant improvement in contrast-to-noise ratios at much shorter scan times than those used in conventional contrast-enhanced T1-weighted spin-echo MR imaging.
本研究旨在评估T1加权快速自旋回波磁共振序列在采集时间短于传统T1加权自旋回波磁共振序列的情况下,为对比增强病变提供更高对比度噪声比的能力。
我们比较了25例患者中32个增强脑病变在T1加权自旋回波(546/10 [TR/TE];两次激发;采集时间,4分12秒)和快速自旋回波(546/10 [TR/有效TE];回波链长度,4;回波间距,10毫秒;两次激发;采集时间,1分45秒)磁共振图像上的对比度噪声比。这些图像是在静脉注射0.10 mmol/kg钆喷酸葡胺后于1.5 T下获得的。
与对比增强T1加权自旋回波磁共振图像相比,对比增强T1加权快速自旋回波磁共振图像显示背景白质的信噪比降低了约12%,而增强病变或脑脊液的信噪比没有随之降低。对比增强T1加权快速自旋回波磁共振图像在增强病变的对比度噪声比方面比对比增强T1加权自旋回波图像提高了23%(p < .001)。
对比增强T1加权快速自旋回波磁共振成像在扫描时间比传统对比增强T1加权自旋回波磁共振成像短得多的情况下,显示出对比度噪声比有统计学意义的提高。