Abstract

Nitrite and nitrate determinations in biological fluids are increasingly being used as markers of nitric oxide production. We have modified a nitrate reductase and Griess reaction method for the measurement of serum nitrate and nitrite in ultrafiltrated samples using a microtitre plate. The recoveries of nitrate and nitrite were 95% (range = 86-113%) and 100% (range = 92-109%), respectively. The intra and inter assay coefficients of variation for nitrate plus nitrite in the concentration range 40-50 microM were 9.1% and 7.8%, and in the concentration range of 2.5-10 microM 23.4% and 25.5%, respectively. At its lower limit the assay is able to detect 125 pmoles of nitrate plus nitrite in 50 microL of sample (2.5 mumol/L). A mean serum nitrate plus nitrite level of 32.8 mumol/L (SD 12.3) was measured in 24 healthy adult volunteers (12 men and 12 women), no age or sex differences were noted.

摘要

生物体液中亚硝酸盐和硝酸盐的测定越来越多地被用作一氧化氮生成的标志物。我们改进了一种硝酸盐还原酶和格里斯反应方法,用于使用微量滴定板测量超滤样品中的血清硝酸盐和亚硝酸盐。硝酸盐和亚硝酸盐的回收率分别为95%(范围=86 - 113%)和100%(范围=92 - 109%)。在40 - 50微摩尔浓度范围内,硝酸盐加亚硝酸盐的批内和批间变异系数分别为9.1%和7.8%,在2.5 - 10微摩尔浓度范围内分别为23.4%和25.5%。该检测方法的下限能够在50微升样品(2.5微摩尔/升)中检测到125皮摩尔的硝酸盐加亚硝酸盐。在24名健康成年志愿者(12名男性和12名女性)中测量的血清硝酸盐加亚硝酸盐平均水平为32.8微摩尔/升(标准差12.3),未发现年龄或性别差异。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验