• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

[The effect of low-dose prostaglandin E1 on intra- and post-operative liver function].

作者信息

Hayashida M, Hanaoka K, Shimada Y, Namiki A, Amaha K

机构信息

Department of Anesthesiology, Faculty of Medicine, University of Tokyo.

出版信息

Masui. 1997 May;46(5):618-27.

PMID:9185458
Abstract

We investigated the effects of low-dose prostaglandin E1 (PGE1) on intra- and post-operative liver function in 109 adult patients undergoing upper abdominal surgery. Patients were divided into 2 groups; Control group (n = 42) and PGE1 group (n = 67). In PGE1 group, PGE1 was infused throughout surgery at a rate of 0.02 microgram kg-1 min-1. In both groups, anesthesia was maintained with a combination of inhalational and thoracic epidural anesthesia. Epidural anesthesia was maintained with 1.5% lidocaine infused epidurally at a constant rate (8 +/- 2 ml.hr-1). The continuous epidural infusion of lidocaine was initiated before surgery and discontinued at the end of surgery. Preoperative and postoperative liver function was evaluated with blood chemistry examination. Intraoperative liver function was evaluated in 84 patients (33 in control group and 51 in PGE1 group) by measuring plasma lidocaine concentration. Plasma lidocaine concentration was determined 1 and 3 hours after the initiation of lidocaine infusion and 0 and 2 hours after its termination. There were no differences between the groups in doses and infusion rates of lidocaine. In both groups, lidocaine concentration increased progressively as infusion was continued. Lidocaine concentration was significantly lower in PGE1 group than in control group at the end of the infusion. In 22 patients in control group and 35 in PGE1 group who received high-dose lidocaine (> 8 mg.kg-1), lidocaine concentration remained significantly lower in PGE1 group than in control group throughout the infusion period. The difference in lidocaine concentrations between the groups increased progressively as infusion was continued, though the doses and the infusion rates of lidocaine were not different between the groups. Postoperative liver function did not differ between the groups. Because removal of lidocaine from blood to liver parallels hepatic blood flow, the lower plasma lidocaine concentration in PGE1 group indicated that hepatic blood flow was higher and liver function was better-maintained with PGE1 during anesthesia and surgery. Low dose PGE1 thus improved intraoperative liver function during upper abdominal surgery.

摘要

相似文献

1
[The effect of low-dose prostaglandin E1 on intra- and post-operative liver function].
Masui. 1997 May;46(5):618-27.
2
[The effect of low-dose prostaglandin E1 on intra- and post-operative renal function].
Masui. 1997 Apr;46(4):464-70.
3
[The effect of low-rose prostaglandin E1 on circulation, respiration and body temperature during surgical anesthesia].[低剂量前列腺素E1对手术麻醉期间循环、呼吸及体温的影响]
Masui. 1997 Mar;46(3):363-72.
4
[Plasma concentration of lidocaine in patients undergoing hepatectomy with continuous epidural anesthesia--influence of extent of hepatectomy and prostaglandin E1 infusion].[连续硬膜外麻醉下肝切除患者的利多卡因血浆浓度——肝切除范围及前列腺素E1输注的影响]
Masui. 1996 May;45(5):624-8.
5
[Effect of prostaglandin E1 infusion during and after total hip arthroplasty under hypotensive anesthesia on postoperative liver function and hemorrhage].[低血压麻醉下全髋关节置换术中及术后输注前列腺素E1对术后肝功能及出血的影响]
Masui. 2002 Apr;51(4):377-81.
6
Prostaglandin E1, lidocaine, and prostaglandin E1-lidocaine combination for attenuating cardiovascular responses to extubation.
Can J Anaesth. 1997 Nov;44(11):1211-4. doi: 10.1007/BF03013348.
7
[Effects of prostaglandin E1 and epidural block on circulatory, hepatic and renal functions during anesthesia for major upper abdominal surgeries].
Masui. 1992 Jul;41(7):1094-100.
8
[Effects of intravenous nicardipine, prostaglandin E1, nitroglycerin, sodium nitroprusside, and epidural lidocaine on hepatic and renal blood flow during hypotensive anesthesia].[静脉注射尼卡地平、前列腺素E1、硝酸甘油、硝普钠以及硬膜外利多卡因对低血压麻醉期间肝血流和肾血流的影响]
Masui. 2000 Dec;49(12):1333-8.
9
[Effects of prostaglandin E1 on plasma cytokine levels during pneumonectomy].[前列腺素E1对肺切除术中血浆细胞因子水平的影响]
Masui. 1996 Mar;45(3):304-8.
10
Effects of prostaglandin E1 on intra-operative central and peripheral temperatures during upper abdominal surgery.前列腺素E1对上腹部手术术中中心体温及外周体温的影响。
Eur J Anaesthesiol. 1995 Jul;12(4):417-22.