Palatinsky E A, Maier K H, Touhalisky D K, Mock J L, Hingson M T, Coker G T
Gliatech Inc., Cleveland, Ohio, USA.
J Hand Surg Br. 1997 Jun;22(3):331-5. doi: 10.1016/s0266-7681(97)80397-x.
Excessive perineural scarring may affect the result of peripheral nerve surgery. The ability of a novel implant material (ADCON-T/N) to prevent this complication was tested in 38 rats. Four weeks after a bilateral sciatic nerve external neurolysis, a secondary bilateral lysis of the adhesions was performed; ADCON-T/N was locally implanted at one side, while the contralateral side was left untreated. Four or 8 weeks later, perineural adhesions were dissected in 24 animals and graded blindly. Significantly fewer perineural adhesions were found in ADCON-T/N treated nerves compared with controls at both 4 and 8 weeks. Residual implant material or adverse effects were not observed at either time. Histological examination of the neurolysis sites in another 14 animals confirmed these findings at both time intervals. This study shows that ADCON-T/N is effective in inhibiting perineural adhesions, is resorbed within 4 weeks and is well tolerated.
过度的神经周围瘢痕形成可能会影响周围神经手术的结果。在38只大鼠中测试了一种新型植入材料(ADCON-T/N)预防这种并发症的能力。在双侧坐骨神经外神经松解术后四周,进行了二次双侧粘连松解术;在一侧局部植入ADCON-T/N,而对侧不进行处理。4周或8周后,对24只动物的神经周围粘连进行解剖并进行盲法分级。在4周和8周时,与对照组相比,ADCON-T/N处理的神经中发现的神经周围粘连明显更少。在两个时间点均未观察到残留的植入材料或不良反应。对另外14只动物的神经松解部位进行组织学检查,在两个时间间隔均证实了这些发现。这项研究表明,ADCON-T/N在抑制神经周围粘连方面有效,在4周内可被吸收,且耐受性良好。