Suppr超能文献

[通过相位对比法(电影相位对比法、快速心脏相位对比法)测量冠状动脉血流]

[The measurement of the coronary flow by the phase contrast method (cine PC, Fastcard PC)].

作者信息

Harada M, Taoka Y, Nishitani H, Nomura M

机构信息

Department of Radiology, University of Tokushima.

出版信息

Nihon Rinsho. 1997 Jul;55(7):1828-32.

PMID:9233035
Abstract

We confirmed the accuracy of flow velocity measured by two kinds of phase contrast (PC) sequence. The fast PC sequence(FCARDPC) showed a little different value from the conventional PC, but the linear correlation was found between established values of the instrument and the measured velocity by the fast PC. The flow velocity of the right and left coronary arteries in one cardiac cycle was measured using two PC sequences on the same subject. It was found that the flow velocity in one cardiac cycle was almost the same pattern between the two method, though the absolute values of each other differed slightly. We considered that the comparison in the same sequence would be acceptable even in clinical cases unless the values measured by a different sequence or modality were compared directly. Though our experience on diseases are still preliminary, we suggest that myocardial ischemia and dysfunction will be related with not only the decrease of velocity but also the change of flow pattern of the coronary artery in one cardiac cycle. We believe that this method has a potential becoming one of the routine methods for evaluating cardiac functions.

摘要

我们证实了两种相位对比(PC)序列所测流速的准确性。快速PC序列(FCARDPC)显示的值与传统PC序列略有不同,但在仪器设定值与快速PC序列所测流速之间发现了线性相关性。在同一受试者身上使用两种PC序列测量了一个心动周期中左右冠状动脉的流速。结果发现,尽管两种方法的绝对值略有差异,但一个心动周期中的流速模式在两种方法之间几乎相同。我们认为,即使在临床病例中,除非直接比较不同序列或模态所测的值,否则在相同序列内进行比较也是可以接受的。尽管我们对疾病的经验仍处于初步阶段,但我们认为心肌缺血和功能障碍不仅与流速降低有关,还与一个心动周期中冠状动脉血流模式的变化有关。我们相信这种方法有潜力成为评估心脏功能的常规方法之一。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验