Baars J W, Nooyen W J, van Beers C, Holtkamp M J, te Velde A, Daleslo O, Slaper-Cortenbach I C, van der Schoot C E, Casteleyn K
Department of Medical Oncology, The Netherlands Cancer Institute, Amsterdam, The Netherlands.
J Clin Apher. 1997;12(2):68-73. doi: 10.1002/(sici)1098-1101(1997)12:2<68::aid-jca3>3.0.co;2-7.
Improvement of the collection efficiency (CE) of the Fenwal CS3000 plus in collecting circulating progenitor cells (CPC) might diminish the number of leukapheresis procedures (LP) required to obtain the CPC required to assure engraftment. We analyzed whether adjustment of the optical setting (location 71,L71) to the number of MNC present in the peripheral blood could enhance the CE of the MNC. Thirty-five patients underwent 121 LP with an adjusted L71. We compared the results retrospectively with 26 LP performed with a fixed L71 (1:100) in 12 patients. The CPC were mobilized with chemotherapy followed by subcutaneous administration of granulocyte colony-stimulating factor (G-CSF) in both groups. Adjustment of the L71 did neither improve the CE of the MNC, the estimated CE of CD34+ cells nor diminished granulocyte contamination. For the total 121 LP with an adjusted L71 and for the total 26 LP with a fixed L71 the mean CE of MNC were, respectively, 44.6 +/- 18.3% and 46.4 +/- 14%. The mean granulocyte contamination, determined by manual white blood cell differentiation, was 1.7 +/- 2.3% for the adjusted L71 group and 2.3 +/- 3 for the fixed L71 group. There was no difference in the median number of LP required to obtain 3 x 10(6) CD34+ cells/kg between both groups. We found a weak significant correlation between WBC and pre-LP MNC count and the CE of MNC (r = 0.36, P = 0.012, resp.r = 0.33, P = 0.023), but no correlation between the CE of MNC and the estimated CE of CD34+ cells (r = 0.24, P = 0.113). In conclusion, adjustment of the L71 to the MNC did not improve the CE of MNC of the Fenwal CS3000. The lack of correlation between the CE and MNC and the estimated CE of CD34+ cells should be further explored.
提高芬华CS3000 plus采集循环祖细胞(CPC)的采集效率(CE)可能会减少为确保植入所需的CPC而进行的白细胞单采程序(LP)的次数。我们分析了将光学设置(位置71,L71)调整为外周血中存在的单核细胞(MNC)数量是否能提高MNC的CE。35例患者接受了121次调整L71后的LP。我们将结果与12例患者进行的26次固定L71(1:100)的LP进行了回顾性比较。两组均采用化疗动员CPC,随后皮下注射粒细胞集落刺激因子(G-CSF)。调整L71既没有提高MNC的CE,也没有提高CD34+细胞的估计CE,也没有减少粒细胞污染。对于121次调整L71的LP和26次固定L71的LP,MNC的平均CE分别为44.6±18.3%和46.4±14%。通过手工白细胞分类测定的平均粒细胞污染,调整L71组为1.7±2.3%,固定L71组为2.3±3%。两组获得3×10(6) CD34+细胞/kg所需的LP中位数没有差异。我们发现白细胞计数和LP前MNC计数与MNC的CE之间存在弱显著相关性(r = 0.36,P = 0.012;r = 0.33,P = 0.023),但MNC的CE与CD34+细胞的估计CE之间没有相关性(r = 0.24,P = 0.113)。总之,将L71调整为MNC并没有提高芬华CS3000的MNC的CE。CE与MNC以及CD34+细胞的估计CE之间缺乏相关性应进一步探讨。