Peripheral blood progenitor cells (PBPC) reside within the mononuclear cell (MNC) component of the blood and can be collected using a number of apheresis devices, including the Fenwal CS3000 Plus Blood Cell Separator. Increased MNC collection efficiency, therefore, may reduce the number of apheresis required to achieve collection goals. In this study, patients were divided into groups by absolute MNC count to determine the effect of interface detector offset (I/O) adjustment on MNC collection efficiency. Apheresis products from 104 procedures collected using a standard I/O setting of 100 were compared with 121 collections for which the I/O setting was adjusted according to the preapheresis MNC count. Adjustment of the I/O setting in this manner had no statistically significant impact on the per kilogram dose of MNC collected. The data did show that MNC collection efficiency was reduced as both the MNC count and I/O setting increased, as the collection efficiency was greatest for patients with the lowest peripheral MNC counts and was inversely correlated with the preapheresis MNC count. Although contamination of the product with platelets was drastically reduced at higher I/O settings, there was a concomitant rise in RBC contamination. We conclude that a standard setting of 100 is preferable to adjustment of the I/O setting as a function of the preapheresis MNC count.

摘要

外周血祖细胞(PBPC)存在于血液的单核细胞(MNC)组分中,可使用多种血液成分分离设备进行采集,包括芬华CS3000 Plus血细胞分离机。因此,提高MNC采集效率可能会减少达到采集目标所需的血液成分分离次数。在本研究中,根据绝对MNC计数将患者分组,以确定界面探测器偏移(I/O)调整对MNC采集效率的影响。将使用100的标准I/O设置采集的104例程序的血液成分分离产品与121例根据血液成分分离前MNC计数调整I/O设置的采集进行比较。以这种方式调整I/O设置对每千克采集的MNC剂量没有统计学上的显著影响。数据确实显示,随着MNC计数和I/O设置的增加,MNC采集效率降低,因为外周MNC计数最低的患者采集效率最高,且与血液成分分离前MNC计数呈负相关。尽管在较高的I/O设置下产品中血小板的污染大幅减少,但红细胞污染随之增加。我们得出结论,100的标准设置比根据血液成分分离前MNC计数调整I/O设置更可取。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验