Da Vela G, Della Lena R, Casini T, Franchini F, Nomellini E B, Salvatore A, Zappulla A, Calabri G B, D'Onghia G, Cardellini L, Murganic V
Laboratorio Analisi Chimico-Cliniche e Microbiologiche, Azienda ospedaliera Anna Meyer di Firenze, Italia.
Pediatr Med Chir. 1997 Jan-Feb;19(1):53-7.
The Authors studied the possibility of using some dip sticks visual for urinalysis. One hundred of urine samples have been analyzed at the beginning with the instrumental laboratory analytical system and then with the dip sticks visual; the results put in evidence that there is a real discrepancy as far as glucose is concerned. Glucose is overestimated in dip sticks visual method. Bilirubin, blood and proteins are in a decreasing order the most different items. Concerning to pH the results have been comparable. Specific weight cannot be compared to the laboratory method, on the other hand it can be used for screening. On the whole the Authors are quite satisfied about dip sticks visual method; it can be used in order to accelerate diagnosis and avoid pre-analytical mistakes.
作者们研究了使用一些尿液分析用的目视比色法试纸条的可能性。一开始,用仪器实验室分析系统对100份尿液样本进行了分析,然后再用目视比色法试纸条进行分析;结果表明,就葡萄糖而言,确实存在差异。在目视比色法中葡萄糖被高估了。胆红素、血液和蛋白质是差异最大的项目,且依次递减。关于pH值,结果具有可比性。比重无法与实验室方法进行比较,但另一方面它可用于筛查。总体而言,作者们对目视比色法试纸条相当满意;它可用于加快诊断并避免分析前的错误。