The extraction of polycyclic aromatic hydrocarbons (PAHs) in water with solid-phase extraction (SPE) discs on a glass fiber matrix has been less studied than other systems such as SPE column extraction or the carbofluor matrix discs. In this paper we have studied SPE discs with a glass fiber matrix (SPE disc GFM) to extract PAHs from aqueous samples, which have then been separated and detected with high-performance liquid chromatography-fluorescence detection. We have found that the proposed method of analysis allows us to obtain detection limits of 0.1 ng/l for benzo[a]pyrene and a variation of 6% in the recovery of said compound at the level of 1 ng/l, and it complies with the required specifications for PAHs in the EU Directive draft on drinking water. The use of GFM discs allows us to shorten the extraction times of PAHs by between 3 and 12 times in comparison with other SPE systems. They can concentrate volume samples of up to 1 l, with PAH recoveries at the level of 1-2 ng/l higher than 80 +/- 10% and detection limits of between 0.1-2 ng/l, depending on the compound studied.
与其他系统(如固相萃取柱萃取或碳氟基质盘)相比,使用玻璃纤维基质的固相萃取(SPE)盘萃取水中多环芳烃(PAHs)的研究较少。在本文中,我们研究了玻璃纤维基质的固相萃取盘(SPE盘GFM)从水样中萃取PAHs,然后用高效液相色谱-荧光检测法进行分离和检测。我们发现,所提出的分析方法能够使我们获得苯并[a]芘的检测限为0.1 ng/l,且在1 ng/l水平下该化合物的回收率变化为6%,并且它符合欧盟饮用水指令草案中对PAHs的要求规范。与其他SPE系统相比,使用GFM盘可使PAHs的萃取时间缩短3至12倍。它们能够浓缩高达1 l的水样,对于1 - 2 ng/l水平的PAHs,回收率高于80±10%,检测限在0.1 - 2 ng/l之间,这取决于所研究的化合物。