Real and simulated clustered microcalcifications in digital mammograms. ROC study of observer performance.

作者信息

Lado M J, Tahoces P G, Souto M, Méndez A J, Vidal J J

机构信息

Department of Radiology, University of Santiago de Compostela, Spain (Complejo Hospitalario Universitario de Santiago).

出版信息

Med Phys. 1997 Sep;24(9):1385-94. doi: 10.1118/1.598027.

Abstract

We have developed a model to simulate clustered microcalcifications on digital mammograms. Wavelet transform techniques were used to detect real clustered microcalcifications. A feature analysis process was applied to automatically extract the features describing the individual simulated microcalcifications and clusters from the values of the real clustered microcalcifications present in the mammogram. Subsequently, a database of simulated and real clustered microcalcifications was created. Clusters of microcalcifications from this database were tested for indistinguishability from real ones. Two radiologists and one physicist were asked to indicate whether the microcalcifications were either real or simulated. The responses of the readers were evaluated with a ROC analysis and the area under the curve was calculated. The average ROC area was 0.54 +/- 0.03, indicating there was no statistical difference between real and simulated clustered microcalcifications. The method allows for the creations of simulated clustered microcalcifications that are virtually indistinguishable from real microcalcifications in digital mammograms and could be used to evaluate different image processing techniques.

摘要

我们开发了一种模型来模拟数字乳腺钼靶片上的簇状微钙化。使用小波变换技术来检测真实的簇状微钙化。应用特征分析过程从乳腺钼靶片中存在的真实簇状微钙化的值中自动提取描述单个模拟微钙化和簇的特征。随后,创建了一个模拟和真实簇状微钙化的数据库。对该数据库中的微钙化簇进行测试,看其是否与真实的难以区分。邀请两名放射科医生和一名物理学家指出微钙化是真实的还是模拟的。用ROC分析评估读者的反应并计算曲线下面积。平均ROC面积为0.54±0.03,表明真实和模拟的簇状微钙化之间没有统计学差异。该方法能够创建在数字乳腺钼靶片中与真实微钙化几乎无法区分的模拟簇状微钙化,可用于评估不同的图像处理技术。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验