Suppr超能文献

用于多切片磁共振成像的动态匀场

Dynamic shimming for multi-slice magnetic resonance imaging.

作者信息

Morrell G, Spielman D

机构信息

Department of Electrical Engineering, Stanford University, California, USA.

出版信息

Magn Reson Med. 1997 Sep;38(3):477-83. doi: 10.1002/mrm.1910380316.

Abstract

Dynamic shimming has been implemented in three pulse sequences on a commercial GE Signa 1.5-T imaging system. Multi-slice field maps are acquired before the imaging sequence, and linear shim terms and center frequencies are calculated for each slice. During the imaging scan, the linear shim terms and center frequency are set before each pulse sequence repetition according to the current slice. Acquisition of multi-slice field maps and calculation of shim terms and center frequency for each slice are accomplished in a matter of seconds. Pulse sequences require only minimal modification to add dynamic shimming capability. Results are shown for a fat saturation spin-echo sequence, a single-shot echo-planar gradient-recalled echo sequence, and a spiral acquisition gradient-recalled echo sequence. In all cases, dynamic shimming with shim currents and center frequency optimized for each slice is shown to give better results than constant shim currents and a single center frequency optimized for the entire volume of interest.

摘要

动态匀场已在商用GE Signa 1.5-T成像系统上的三个脉冲序列中实现。在成像序列之前采集多层面场图,并为每个层面计算线性匀场项和中心频率。在成像扫描期间,根据当前层面在每个脉冲序列重复之前设置线性匀场项和中心频率。多层面场图的采集以及每个层面的匀场项和中心频率的计算在几秒钟内即可完成。脉冲序列只需进行最小程度的修改即可添加动态匀场功能。给出了脂肪饱和自旋回波序列、单次激发回波平面梯度回波序列和螺旋采集梯度回波序列的结果。在所有情况下,针对每个层面优化匀场电流和中心频率的动态匀场均显示出比针对整个感兴趣体积优化的恒定匀场电流和单个中心频率能产生更好的结果。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验