Dickson M A, Moores C, McClure J H
Department of Anaesthetics, Royal Infirmary of Edinburgh.
Br J Anaesth. 1997 Sep;79(3):297-300. doi: 10.1093/bja/79.3.297.
Single, end-holed and multi-orifice extradural catheters were compared in terms of efficacy and complications when used for infusion of 0.1% bupivacaine during labour. In this study of 364 patients there was no difference in unilateral block after an initial bolus dose (18 (11.5%) for single, end-holed and 16 (10.9%) for multi-orifice catheters). Unilateral block recurred with seven (4.0%) single, end-holed and with eight (4.8%) multi-orifice catheters. Unilateral blocks, arising for the first time during infusion of local anaesthetic, occurred significantly more frequently when single, end-holed catheters were used (29 (16.4%)) compared with multi-orifice catheters (14 (8.4%)) (P < 0.05).