Krause W R, Pope M H, Johnson R J, Wilder D G
J Bone Joint Surg Am. 1976 Jul;58(5):599-604.
A compression testing machine was used to transmit increasing loads at various strain rates across twelve canine and twelve human cadaver knees. The specimens were originally evaluated with both menisci intact and the same tests were repeated with one meniscus removed and then with both menisci removed. This investigation showed that the menisci perform a load-transmitting and energy-absorbing function in the knee joint. The stress acting across the joint increased significantly after meniscectomy. The intact meniscus was deformed during compressive loading rather than being passively pushed away, thus demonstrating the presence of hoop stresses within the meniscus.
一台压缩试验机被用于在不同应变率下对十二具犬类和十二具人类尸体膝关节施加逐渐增加的负荷。最初在两个半月板均完整的情况下对标本进行评估,然后在切除一个半月板以及切除两个半月板后重复相同的测试。这项研究表明,半月板在膝关节中发挥着负荷传递和能量吸收的功能。半月板切除术后,作用于关节的应力显著增加。完整的半月板在压缩负荷下发生变形,而不是被被动推开,从而证明半月板内存在环向应力。