Bahner M L, Reith W, Zuna I, Engenhart-Cabillic R, van Kaick G
Department of Radiology, German Cancer Research Center, Im Neuenheimer Feld 280, D-69 120 Heidelberg, Germany.
Eur Radiol. 1998;8(3):416-20. doi: 10.1007/s003300050403.
The aim of this study was to evaluate image quality of spiral CT of the brain as compared with incremental CT using identical scanning parameters. Incremental or spiral cranial CT was performed on 46 consecutive, randomized patients with non-traumatic disease of the brain on a Siemens (Erlangen, Germany) Somatom Plus 4. Evaluation was done in a randomized blinded way by two experienced radiologists. Different anatomical structures, image noise, and artifacts were scaled 1 (bad) to 4 (very good). Statistical analysis was done using the F-test of variance for partial sums of squares as well as Student's t-test. Incremental CT was superior to spiral CT for evaluation of the internal capsule, supratentorial artifacts, gray/white matter differentiation, and image noise. No statistically significant differences were seen for evaluation of the pons, infratentorial artifacts, and eye muscles. With identical scanning parameters incremental CT is superior to spiral CT in the assessment of small, complex structures in a low-contrast setting. No differences are seen for larger structures or small structures in a medium-contrast range. Artifacts localized close to the skull in spiral CT can easily mimic hemorrhage in traumatized patients. Spiral CT should therefore only be used for CT angiography and if 3D reconstructions are needed.
本研究的目的是在相同扫描参数下,将脑部螺旋CT的图像质量与增量CT进行比较。对46例连续的、随机选取的患有非创伤性脑部疾病的患者,在西门子(德国埃尔兰根)Somatom Plus 4上进行增量或螺旋头颅CT扫描。由两名经验丰富的放射科医生以随机盲法进行评估。对不同的解剖结构、图像噪声和伪影进行1(差)至4(非常好)的评分。使用方差分析的F检验以及学生t检验进行统计分析。在评估内囊、幕上伪影、灰质/白质区分和图像噪声方面,增量CT优于螺旋CT。在评估脑桥、幕下伪影和眼肌方面,未观察到统计学上的显著差异。在相同扫描参数下,在低对比度环境中评估小的复杂结构时,增量CT优于螺旋CT。在中等对比度范围内,对于较大结构或小结构,未观察到差异。螺旋CT中靠近颅骨的伪影在创伤患者中容易模拟出血。因此,螺旋CT仅应用于CT血管造影以及需要进行三维重建的情况。