Collison I B, Spiehler V R, Guluzian S, Sedgwick P R
Forensic Science Services, Santa Ana, CA, USA.
J Forensic Sci. 1998 Mar;43(2):390-4.
The objective of this study was to establish the optimum immunoassay cutoff concentrations for screening postmortem blood from coroner's cases for drugs of abuse with a coated tube radioimmunoassay (RIA) to ensure that the results with the coated tube RIA would be equal to or better than those with the previously used double antibody RIA. Immunoassay results (positive or negative) blood were compared to confirmed results on those cases by GC/MS alone or in combination with GLC using either a NPD or FID detector. Four to seven potential cutoff concentrations were evaluated for the drug classes opiates, amphetamines, cocaine and metabolites, and barbiturates. Specimens were 350 postmortem blood specimens and liver homogenates. The cutoffs chosen for the coated tube RIA using this approach were 5 ng/mL morphine, 25 ng/mL methamphetamine, 500 ng/mL benzoylecgonine, and 500 ng/mL secobarbital. These cutoffs corresponded to a sensitivity and specificity of 94% and 96% for opiates, 93% and 86% for amphetamines, 91% and 96% for cocaine and metabolites and 91% and 87% for barbiturates. The double antibody RIAs were run on the same specimens with cutoffs of 20 ng/mL morphine, 50 ng/mL methamphetamine, 50 ng/mL benzoylecgonine and 1000 ng/mL phenobarbital. The sensitivity and specificity's for the double antibody immunoassay were: > 99% and 96% for opiates, 83% and 89% for amphetamines, 98% and 97% for cocaine, 79% and 95% for barbiturates.
本研究的目的是确定用于筛查死因裁判官案件尸检血液中滥用药物的最佳免疫分析临界浓度,采用包被管放射免疫分析(RIA),以确保包被管RIA的结果等同于或优于先前使用的双抗体RIA。将免疫分析结果(阳性或阴性)与仅通过气相色谱/质谱联用仪(GC/MS)或结合使用氮磷检测器(NPD)或火焰离子化检测器(FID)的气相色谱仪(GLC)对这些病例进行确认的结果进行比较。对阿片类药物、苯丙胺类、可卡因及其代谢物和巴比妥类药物的潜在临界浓度进行了四至七次评估。样本为350份尸检血液样本和肝脏匀浆。采用这种方法为包被管RIA选择的临界值为:吗啡5 ng/mL、甲基苯丙胺25 ng/mL、苯甲酰爱康宁500 ng/mL和司可巴比妥500 ng/mL。这些临界值对应的阿片类药物灵敏度和特异性分别为94%和96%,苯丙胺类为93%和86%,可卡因及其代谢物为91%和96%,巴比妥类为91%和87%。双抗体RIA在相同样本上进行检测,吗啡的临界值为20 ng/mL、甲基苯丙胺为50 ng/mL、苯甲酰爱康宁为50 ng/mL、苯巴比妥为1000 ng/mL。双抗体免疫分析的灵敏度和特异性分别为:阿片类药物>99%和96%,苯丙胺类为83%和89%,可卡因为98%和97%,巴比妥类为79%和95%。