Suppr超能文献

Measurement of nasal irritant sensitivity to pulsed carbon dioxide: a pilot study.

作者信息

Shusterman D, Balmes J

机构信息

Division of Occupational and Environmental Medicine, University of California-San Francisco 94143-0843, USA.

出版信息

Arch Environ Health. 1997 Sep-Oct;52(5):334-40. doi: 10.1080/00039899709602208.

Abstract

Nasal irritation and associated symptoms (e.g., nasal congestion, rhinorrhea, sinus headache) are important air-pollution-related health complaints, particularly in so-called problem buildings. Individual differences in nasal irritant sensitivity are therefore of both clinical and regulatory interest. To document such differences, one must first functionally define perceptual acuity to airborne irritants. In an adaptation of an established sensory testing method, the authors used the odorless irritant carbon dioxide in an electronically controlled dilution apparatus to deliver brief (approximately 3 s) pulses at controlled levels (10%-70%, vol/vol), synchronized with the inspiratory phase of the respiratory cycle. Investigators who use this apparatus can use a variant of the forced-choice paradigm for threshold determination to document nasal irritant sensitivity. The authors recruited 30 adult volunteers (17 males, 13 females; average age = 41 y, range = 19-79 y) from a university laboratory complex and from the general community. Within this group, there was a skewed distribution of carbon dioxide thresholds (arithmetic mean = 28%, geometric mean = 27% [vol/vol]). In univariate analyses, geometric mean carbon dioxide thresholds differed significantly with respect to smoking status (36% carbon dioxide in smokers versus 25% in nonsmokers; p < .005), but not with respect to age, gender, or self-reported history of allergic rhinitis. In a multivariate analysis, gender also approached significance; females tended to show better perceptual acuity than males (p = .06). Neither self-reported "vasomotor rhinitis" symptoms nor self-reported symptomatic reactivity to environmental tobacco smoke predicted carbon dioxide thresholds. Pulsed carbon dioxide is well tolerated by subjects who participate in a threshold detection task; the procedure yields a potential endpoint with which to compare individuals (and groups) with respect to nasal irritant perceptual acuity. The relationship between such acuity and nasal physiologic reactivity-as well as the generalizability of such measures to other, more environmentally realistic irritants-has yet to be defined.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验