Suppr超能文献

呼气期高分辨率CT扫描显示空气潴留而吸气期扫描无异常:与肺功能检查的相关性及鉴别诊断

Air trapping on expiratory high-resolution CT scans in the absence of inspiratory scan abnormalities: correlation with pulmonary function tests and differential diagnosis.

作者信息

Arakawa H, Webb W R

机构信息

Department of Radiology, University of California, San Francisco 94143-0628, USA.

出版信息

AJR Am J Roentgenol. 1998 May;170(5):1349-53. doi: 10.2214/ajr.170.5.9574614.

Abstract

OBJECTIVE

We wish to describe the differential diagnosis and pulmonary function correlates of patients with normal findings on inspiratory high-resolution CT (HRCT) scans who showed air trapping on expiratory scans.

MATERIALS AND METHODS

HRCT scans in 273 consecutive patients with suspected diffuse lung disease were reviewed. HRCT consisted of inspiratory scans at 1- to 2-cm intervals and expiratory scans at three levels. Studies considered to show expiratory air trapping were divided into two groups, one having normal findings on inspiratory scans and one having abnormal findings on inspiratory scans. Pulmonary function test results in these groups were compared with a group of patients who had normal findings on inspiratory and expiratory HRCT scans.

RESULTS

Forty-five patients showed air trapping on expiratory HRCT scans. Of these 45 patients, inspiratory high-resolution CT scans showed abnormal findings in 36 (bronchiectasis, bronchiolitis obliterans, asthma, chronic bronchitis, and cystic fibrosis). In the remaining nine patients, inspiratory HRCT had normal findings; conditions in these nine patients included bronchiolitis obliterans (n = 5), asthma (n = 3), and chronic bronchitis (n = 1). Results of pulmonary function tests in patients with air trapping and normal findings on inspiratory scans were intermediate, falling between those of patients with normal findings on inspiratory and expiratory HRCT scans and those of patients with air trapping and abnormal findings on inspiratory scans.

CONCLUSION

Air trapping on expiratory HRCT scans in patients with normal findings on inspiratory scans is most often associated with bronchiolitis obliterans and asthma. Obtaining expiratory scans in patients who may have one of these diseases is recommended.

摘要

目的

我们希望描述吸气期高分辨率CT(HRCT)扫描结果正常但呼气期扫描显示空气潴留的患者的鉴别诊断及肺功能相关性。

材料与方法

回顾了连续273例疑似弥漫性肺疾病患者的HRCT扫描。HRCT包括间隔1至2厘米的吸气期扫描和三个层面的呼气期扫描。被认为显示呼气期空气潴留的研究分为两组,一组吸气期扫描结果正常,另一组吸气期扫描结果异常。将这些组的肺功能测试结果与吸气期和呼气期HRCT扫描结果均正常的一组患者进行比较。

结果

45例患者呼气期HRCT扫描显示空气潴留。在这45例患者中,36例吸气期高分辨率CT扫描显示异常(支气管扩张、闭塞性细支气管炎、哮喘、慢性支气管炎和囊性纤维化)。其余9例患者吸气期HRCT结果正常;这9例患者的情况包括闭塞性细支气管炎(n = 5)、哮喘(n = 3)和慢性支气管炎(n = 1)。吸气期扫描结果正常但有空气潴留的患者的肺功能测试结果处于中间水平,介于吸气期和呼气期HRCT扫描结果均正常的患者与吸气期扫描结果异常且有空气潴留的患者之间。

结论

吸气期扫描结果正常的患者呼气期HRCT扫描出现空气潴留最常与闭塞性细支气管炎和哮喘相关。建议对可能患有这些疾病之一的患者进行呼气期扫描。