二尖瓣位置猪主动脉生物瓣膜的超声心动图。

Echocardiogram of the porcine aortic bioprosthesis in the mitral position.

作者信息

Bloch W N, Felner J M, Wickliffe C, Symbas P N, Schlant R C

出版信息

Am J Cardiol. 1976 Sep;38(3):293-8. doi: 10.1016/0002-9149(76)90170-3.

Abstract

Echocardiography was performed in 10 consecutive patients who had a clinically normally functioning porcine aortic bioprosthesis in the mitral position. Strong well defined echoes were recorded from the anterior and posterior aspects of the xenograft stent. The maximal separation of the anterior and posterior stent echoes approximated the diameter of the stent at its base. The maximal excursion of the anterior stent was 5 to 10 mm (mean 7.5) with a mean systolic slope of 15 to 35 mm/sec (mean 22.2) and diastolic slope of 11 to 59 mm/sec (mean 21.5). In all 10 patients it was possible to record an anterior xenograft leaflet with anterior movement at the onset of diastole and posterior movement at the onset of systole and with appropriately steep (more than 200 mm/sec) slopes. The diastolic (E-F) slope of the anterior leaflet in 9 of the 10 patients ranged from 9 to 38 mm/sec (mean 19). In 6 of the 10 patients a posterior xenograft leaflet with a movement pattern symmetric with that of the anterior leaflet was recorded. In two patients, the central aortic leaflet was recorded with little diastolic displacement. These two patients also had mild aortic regurgitation, which was associated with diastolic shudder of the xenograft leaflets. Echocardiography was also performed in one patient who was later shown to have a 10 cm3 thrombus on the ventricular surface of a xenograft valve. The echocardiogram in this patient revealed the following abnormalities: (1) excessive anterior stent movement and systolic slope suggesting paravalvular leak in the presence of abnormal cinefluoroscopic valve tilt, and (2) multiple dense nonhomogeneous echoes between the anterior and posterior aspects of the valve stent, with an early diastolic clear space behind the anterior stent and abnormal echoes behind the posterior stent during systole. Echocardiography therefore appears to be useful in evaluating the porcine aortic bioprosthesis in the mitral position.

摘要

对10例二尖瓣位猪主动脉生物瓣临床功能正常的连续患者进行了超声心动图检查。在异种移植支架的前后表面记录到了清晰的强回声。前后支架回声的最大间距接近支架底部的直径。前支架的最大偏移为5至10毫米(平均7.5毫米),平均收缩期斜率为15至35毫米/秒(平均22.2毫米/秒),舒张期斜率为11至59毫米/秒(平均21.5毫米/秒)。在所有10例患者中,均可记录到一个前异种移植瓣叶,其在舒张期开始时向前移动,在收缩期开始时向后移动,且斜率适当陡峭(超过200毫米/秒)。10例患者中有9例的前瓣叶舒张期(E-F)斜率为9至38毫米/秒(平均19毫米/秒)。10例患者中有6例记录到了一个后异种移植瓣叶,其运动模式与前瓣叶对称。在2例患者中,记录到中央主动脉瓣叶舒张期移位很小。这2例患者还存在轻度主动脉瓣反流,与异种移植瓣叶的舒张期震颤有关。还对1例患者进行了超声心动图检查,该患者后来在异种移植瓣膜的心室表面发现有一个10立方厘米的血栓。该患者的超声心动图显示出以下异常:(1)前支架过度移动和收缩期斜率,提示在异常电影荧光透视瓣膜倾斜的情况下存在瓣周漏;(2)瓣膜支架前后表面之间有多个密集的不均匀回声,前支架后方在舒张早期有一个清晰区,后支架后方在收缩期有异常回声。因此,超声心动图似乎有助于评估二尖瓣位的猪主动脉生物瓣。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验