Sun R, Gimbel H V
Gimbel Eye Centre, Calgary, Alberta, Canada.
Ophthalmic Surg Lasers. 1998 Jun;29(6):502-5.
In vitro evaluation of the capsular tension ring for managing zonular dialysis in cataract surgery.
Pig and cadaver eye models were used in this study. Lens material was removed with phacoemulsification, then the zonules were cut in one quadrant of the meridian to induce capsular bag decentration. Posterior chamber intraocular lenses (PC IOLs) were implanted into the bag with or without the tension rings. The IOL and the tension ring positions were viewed using the Miyaki technique. PC IOLs were also implanted into isolated capsular bags with or without tension rings, and bag configuration was examined.
The IOL decentration was observed when the IOLs were implanted into the eyes without zonular support in one quadrant of the meridian. No IOL decentration was observed when the tension ring and the IOL were implanted together. When only the IOLs were inserted into the isolated bags they became oval, whereas the circular bags were preserved when both the IOL and the tension ring were placed in-the-bag.
The authors' in vitro model demonstrated that the capsular tension ring maintained the circular contour of the capsular bag and IOL centration in the eyes with broken zonules. The results suggest that capsular tension rings may provide an alternative means to manage zonular dialysis during phacoemulsification and PC IOL implantation.
白内障手术中用于处理悬韧带断裂的囊袋张力环的体外评估。
本研究使用猪眼和尸体眼模型。用超声乳化术去除晶状体物质,然后在子午线的一个象限切断悬韧带以诱导囊袋偏心。有或没有张力环的情况下,将后房型人工晶状体(PC IOL)植入囊袋。使用宫崎技术观察人工晶状体和张力环的位置。有或没有张力环的情况下,也将PC IOL植入分离的囊袋中,并检查囊袋形态。
当将人工晶状体植入子午线一个象限无悬韧带支撑的眼中时,观察到人工晶状体偏心。当张力环和人工晶状体一起植入时,未观察到人工晶状体偏心。仅将人工晶状体插入分离的囊袋时,它们会变成椭圆形,而当人工晶状体和张力环都置于囊袋中时,圆形囊袋得以保留。
作者的体外模型表明,囊袋张力环可维持悬韧带断裂眼中囊袋的圆形轮廓以及人工晶状体的居中。结果提示,囊袋张力环可能为超声乳化术和PC IOL植入过程中处理悬韧带断裂提供一种替代方法。