Cook L T, Cox G G, Insana M F, McFadden M A, Hall T J, Gaborski R S, Lure F Y
Department of Radiology, Kansas University Medical Center, Kansas City 66160-7234, USA.
Med Phys. 1998 Jul;25(7 Pt 1):1132-8. doi: 10.1118/1.598304.
The goal of the study was to compare a cathode-ray-tube (CRT) digital display with film by using task-dependent image quality assessment methods. Contrast-detail analysis was utilized. Human observers performed a simple detection task, specifically, detecting a pillbox target in a uniform Poisson field, using either film or a digital display that employed a CRT monitor. Observers performed equally well on both film and CRT when the window settings of the digital display were established subjectively by a radiologist. Changing the window settings of the digital display to match the average background luminance of a film-illuminator combination decreased the luminance contrast of the targets and observer performance was reduced, though these effects were probably not linked. The "gold standard" film had lower luminance contrast than the CRT displayed images, yet observer performance was never lower for film than for the CRT. Therefore we concluded that luminance contrast was not a limiting factor for observer performance in this study. The CRT monitor changed fairly rapidly after it was calibrated. During a period of six months the gamma of the display increased from 1.82 to 2.42 and the maximum luminance decreased from 319 to 228 cd/m2. Low luminance output demonstrated a larger percentage decrease (approximately equal to 85%) than high luminance output (approximately equal to 29%) over the same time period. These observations suggest that standard window settings should be reviewed from time to time to ensure that the display is used optimally. No special look-up table setup such as perceptual linearization was used.
本研究的目的是通过使用与任务相关的图像质量评估方法,将阴极射线管(CRT)数字显示器与胶片进行比较。采用了对比度细节分析。人类观察者执行一项简单的检测任务,具体而言,使用胶片或配备CRT显示器的数字显示器,在均匀的泊松场中检测药盒目标。当数字显示器的窗口设置由放射科医生主观确定时,观察者在胶片和CRT上的表现同样出色。将数字显示器的窗口设置更改为与胶片照明器组合的平均背景亮度相匹配,会降低目标的亮度对比度,并且观察者的表现会下降,不过这些影响可能并无关联。“金标准”胶片的亮度对比度低于CRT显示的图像,但胶片的观察者表现从未低于CRT。因此,我们得出结论,亮度对比度不是本研究中观察者表现的限制因素。CRT显示器在校准后变化相当快。在六个月的时间里,显示器的伽马值从1.82增加到2.42,最大亮度从319 cd/m²降至228 cd/m²。在同一时间段内,低亮度输出的下降百分比(约等于85%)高于高亮度输出(约等于29%)。这些观察结果表明,应不时审查标准窗口设置,以确保显示器得到最佳使用。未使用诸如感知线性化等特殊的查找表设置。