Abstract

The present work investigates the corrosion behavior of 2205 duplex stainless steel in 0.9% NaCl solution after various heat-treatments, and compares it to that of 316L austenitic stainless steel. Both stainless steels were heat-treated at 500, 650, and 800 degrees C in air for 1 h, followed by furnace cooling. Each heat-treated sample was examined for their microstructures and Vickers micro-hardness, and subjected to the X-ray diffraction for the phase identification. Using potentiostatic polarization method, each heat-treated sample was corrosion-tested in 37 degrees C 0.9% NaCl solution to estimate its corrosion rate. It was found that simulated sensitization showed an adverse influence on both steels, indicating that corrosion rates increased by increasing the sensitization temperatures.

摘要

本研究调查了2205双相不锈钢在不同热处理后在0.9%氯化钠溶液中的腐蚀行为,并将其与316L奥氏体不锈钢的腐蚀行为进行比较。两种不锈钢均在空气中于500、650和800摄氏度下热处理1小时,然后炉冷。对每个热处理后的样品进行微观结构和维氏显微硬度检查,并进行X射线衍射以进行相鉴定。使用恒电位极化法,在37摄氏度的0.9%氯化钠溶液中对每个热处理后的样品进行腐蚀测试,以估计其腐蚀速率。结果发现,模拟敏化对两种钢都有不利影响,表明腐蚀速率随敏化温度的升高而增加。