Assessment of the influence of citrate concentration on the International Normalized Ratio (INR) determined with twelve reagent-instrument combinations.

作者信息

Chantarangkul V, Tripodi A, Clerici M, Negri B, Mannucci P M

机构信息

Angelo Bianchi Bonomi Hemophilia and Thrombosis Centre, Institute of Internal Medicine, University and IRCCS Maggiore Hospital, Milan, Italy.

出版信息

Thromb Haemost. 1998 Aug;80(2):258-62.

PMID:9716149
Abstract

Citrate concentration is one of the variables that can affect coagulation tests. However, few studies have so far been performed to assess the magnitude of this effect on coagulation tests in general and PT in particular. The aim of this study was to assess the extent of influence of citrate concentration on the PT test with results expressed as INR. Twelve reagent-instrument combinations (systems) were calibrated vs. the Reference Preparation BCT/441 using plasmas collected in either 105 mM or 129 mM citrate from normals and anticoagulated patients (OAT). PTs for plasmas collected in 129 mM citrate were longer than those collected in 105 mM both for normals and patients on OAT, but the ratios (patient-to-normal clotting times) for the two citrate concentrations were significantly different in many instances, implying that the International Sensitivity Index (ISI) is also different. ISIs for calibrations with plasmas collected in 105 mM were greater (up to 10%) than those with plasmas collected in 129 mM citrate. When PT ratios were transformed into INR using crossover ISIs (i.e., plasmas collected in 105 mM and ISI determined with plasmas collected in 129 mM citrate, or vice versa) we found that an INR of 4.5 could be up to 20% apart from the value that would have been obtained if the appropriate ISI was used. Moreover, if the ISI determined with the manual technique was used to convert PTs obtained with a particular instrument into INR, the effect of citrate concentration was even greater (INR difference up to 64%). Should these observations be valid for other systems, they might provide additional explanations for the frequent reports which document discrepancies in the INR determined with different systems to which incorrect ISI might have been applied. World-wide consensus on a single citrate concentration to collect patients' as well as lyophilized plasmas to be used in External Quality Assessment Schemes and for local system calibration is therefore urgently needed.

摘要

相似文献

1
Assessment of the influence of citrate concentration on the International Normalized Ratio (INR) determined with twelve reagent-instrument combinations.
Thromb Haemost. 1998 Aug;80(2):258-62.
2
A comparison of INRs after local calibration of thromboplastin international sensitivity indexes.凝血活酶国际敏感指数局部校准后国际标准化比值的比较。
Clin Lab Sci. 2002 Spring;15(2):91-5.
3
Multicenter evaluation of lyophilized and deep-frozen plasmas for assignment of the International Normalized Ratio.用于国际标准化比值测定的冻干血浆和深冻血浆的多中心评估。
Thromb Haemost. 1999 Nov;82(5):1451-5.
4
Calibration of local systems with lyophilized calibrant plasmas improves the interlaboratory variability of the INR in the Italian external quality assessment scheme.使用冻干校准血浆对本地系统进行校准,可改善意大利外部质量评估计划中INR的实验室间变异性。
Thromb Haemost. 1999 Dec;82(6):1621-6.
5
Use of EDTA samples for prothrombin time measurement in patients receiving oral anticoagulants.在接受口服抗凝剂治疗的患者中使用乙二胺四乙酸(EDTA)样本进行凝血酶原时间测定。
Haematologica. 2001 Aug;86(8):851-5.
6
Evaluation of frozen plasma calibrants for enhanced standardization of the international normalized ratio (INR): a multi-center study.用于国际标准化比值(INR)强化标准化的冷冻血浆校准物评估:一项多中心研究。
Thromb Haemost. 2002 Jan;87(1):74-9.
7
Standardization of coagulation tests.凝血试验的标准化。
Southeast Asian J Trop Med Public Health. 1999;30 Suppl 3:79-85.
8
Discrepant sensitivity of thromboplastin reagents to clotting factor levels explored by the prothrombin time in patients on stable oral anticoagulant treatment: impact on the international normalized ratio system.通过凝血酶原时间探讨稳定口服抗凝治疗患者中凝血活酶试剂对凝血因子水平的差异敏感性:对国际标准化比值系统的影响
Haematologica. 2002 Dec;87(12):1265-73.
9
Influence of three types of automated coagulometers on the international sensitivity index (ISI) of rabbit, human, and recombinant human tissue factor preparations--a multicenter study.
Thromb Haemost. 1999 Jan;81(1):66-70.
10
Effect of concentration of trisodium citrate anticoagulant on calculation of the International Normalised Ratio and the International Sensitivity Index of thromboplastin.枸橼酸钠抗凝剂浓度对国际标准化比值及凝血活酶国际敏感指数计算的影响
Thromb Haemost. 1994 Jul;72(1):84-8.

引用本文的文献

1
Influence of blood collection systems on coagulation tests.采血系统对凝血试验的影响。
Turk J Haematol. 2012 Dec;29(4):367-75. doi: 10.5505/tjh.2012.59254. Epub 2012 Dec 5.
2
Clinical utilization of the international normalized ratio (INR).国际标准化比值(INR)的临床应用。
J Clin Lab Anal. 2000;14(3):101-14. doi: 10.1002/(sici)1098-2825(2000)14:3<101::aid-jcla4>3.0.co;2-a.