使用全身体积描记器测量支气管收缩:自由活动豚鼠与束缚豚鼠的比较

Measurement of bronchoconstriction using whole-body plethysmograph: comparison of freely moving versus restrained guinea pigs.

作者信息

Chong B T, Agrawal D K, Romero F A, Townley R G

机构信息

Allergic Disease Center, Creighton University School of Medicine, Omaha, NE 68178, USA.

出版信息

J Pharmacol Toxicol Methods. 1998 Apr;39(3):163-8. doi: 10.1016/s1056-8719(98)00021-5.

Abstract

We have previously measured pulmonary function in guinea pigs using a double-chambered plethysmograph, however, the question remains regarding the accuracy of the double-chamber to gauge the long-term pulmonary function of late asthmatic response. This may be affected by confounding factors, such as stress on the animal and differences in size of the collar around the neck. Therefore, in this study we compared histamine-induced bronchoconstriction in the same guinea pigs using a single- versus a double-chambered body box. In the double-chambered body box, the specific airway resistance is proportional to time delay between thoracic and nasal flows and measured in cmH2O x s. Whereas, in the single-chambered body box, PenH units (Enhanced Pause) reflect "effort of breathing." This is measured as the pause between inspiration and expiration. Doubling concentrations of histamine (12.5-200 microg/ml dissolved in normal saline) were administered by DeVilbiss nebulizer for 1 min, followed by 1 min suction of residual drug in the chamber, and then the airway resistance was recorded by the computer for the following 3 min. There was a 15-min wash-out period between two doses of histamine. There was no statistically significant difference (p > 0.05) in the PC100 values for histamine between the two methods, however, it was much easier to work with the single-chambered body box in terms of handling the animal and eliminating the possible influence of collar placement on the bronchoconstriction. In conclusion, the data suggests histamine challenges produce equivalent PC100 data in both the double-chambered plethysmograph with sRAW units and single-chambered plethysmograph using the PenH units.

摘要

我们之前使用双腔体积描记器测量了豚鼠的肺功能,然而,关于双腔测量迟发性哮喘反应长期肺功能的准确性问题仍然存在。这可能会受到混杂因素的影响,比如动物的应激以及颈部项圈大小的差异。因此,在本研究中,我们比较了同一批豚鼠使用单腔与双腔体盒时组胺诱导的支气管收缩情况。在双腔体盒中,特定气道阻力与胸廓和鼻腔气流之间的时间延迟成正比,以厘米水柱×秒为单位进行测量。而在单腔体盒中,PenH单位(增强暂停)反映“呼吸努力”。这是通过吸气和呼气之间的暂停来测量的。用德维比斯雾化器给予双倍浓度的组胺(12.5 - 200微克/毫升溶解于生理盐水中)1分钟,随后在腔室内抽吸残留药物1分钟,然后计算机记录接下来3分钟的气道阻力。两剂组胺之间有15分钟的洗脱期。两种方法之间组胺的PC100值没有统计学显著差异(p > 0.05),然而,就处理动物以及消除项圈放置对支气管收缩的可能影响而言,使用单腔体盒操作起来要容易得多。总之,数据表明组胺激发试验在使用sRAW单位的双腔体积描记器和使用PenH单位的单腔体积描记器中产生的PC100数据相当。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验