Seventy-eight limbs of forty-eight patients undergoing total hip replacement were studied by roentgenographic phlebography, cuff-impedance phlebography, and 125I fibrinogen scanning. Compared with roentgenographic phlebography, cuff-impedance phlebography detected seven of ten thrombi in the thigh but none of nine thrombi in the calf and popliteal veins, giving an over-all accuracy of 80 per cent. The 125I fibrinogen scanning technique detected none of the ten thrombi in the thigh and seven of the nine in the calf and popliteal veins, giving an over-all accuracy of 78 per cent. Combining the results of the two techniques, fourteen of the nineteen thrombi were detected. Cuff-impedance phlebography appears to be a useful method for the diagnosis of thrombi in the thigh after hip surgery.
对48例接受全髋关节置换术患者的78条肢体进行了X线静脉造影、袖带阻抗静脉造影和125I纤维蛋白原扫描研究。与X线静脉造影相比,袖带阻抗静脉造影检测出大腿部10个血栓中的7个,但小腿和腘静脉的9个血栓均未检测出,总体准确率为80%。125I纤维蛋白原扫描技术未检测出大腿部10个血栓中的任何一个,检测出小腿和腘静脉9个血栓中的7个,总体准确率为78%。将两种技术的结果相结合,检测出了19个血栓中的14个。袖带阻抗静脉造影似乎是诊断髋关节置换术后大腿血栓的一种有用方法。