INTRODUCTION

Transcranial Doppler pulsatility index was reported clinically to increase when cerebral perfusion pressure decreased, hypothetically marking the lower limit of cerebral autoregulation. We sought to investigate the relationship between pulsatility index, cerenbrovascular resistance, and cerebral perfusion pressure in various states of autoregulation in an animal model of moderate intracranial hypertension.

METHOD

Eight New-Zealand White Rabbits were studied with basilar artery blood flow velocity (ultrasound Doppler) and cortical blood flow (laser Doppler) monitored continuously during subarachnoid saline infusion to increase intracranial pressure (< 55 mm Hg). Four animals demonstrated a stable cortical blood flow, and four demonstrated decreasing blood flow when cerebral perfusion pressure decreased.

RESULTS

Pulsatility index showed the same pattern of increase when cerebral perfusion pressure decreased, independent on whether cortical blood flow was stable or falling. The percentage rate of increase in the pulsatility index was not different in autoregulating and non autoregulating animals. The rate of decrease in cerebrovascular resistance was significantly lower (p < 0.05) in non-autoregulating than in autoregulating animals.

CONCLUSION

The increase in transcranial Doppler pulsatility index when cerebral perfusion pressure falls cannot be interpreted as a phenomenon able to mark the lower limit of cerebral autoregulation.

摘要

引言

临床报道称,当脑灌注压降低时,经颅多普勒搏动指数会升高,据此推测这标志着脑自动调节的下限。我们试图在中度颅内高压动物模型中,研究搏动指数、脑血管阻力和脑灌注压在各种自动调节状态下的关系。

方法

对8只新西兰白兔进行研究,在蛛网膜下腔注入生理盐水以升高颅内压(<55mmHg)的过程中,持续监测基底动脉血流速度(超声多普勒)和皮质血流(激光多普勒)。4只动物的皮质血流稳定,另外4只在脑灌注压降低时血流减少。

结果

当脑灌注压降低时,搏动指数呈现相同的升高模式,与皮质血流是稳定还是下降无关。搏动指数的升高百分比在自动调节和非自动调节的动物中没有差异。非自动调节动物的脑血管阻力下降速率显著低于自动调节动物(p<0.05)。

结论

脑灌注压下降时经颅多普勒搏动指数的升高不能被解释为能够标志脑自动调节下限的现象。