Tattam D A, Allen D A, Beynon T D, Constantine G, Green S, Scott M C, Weaver D R
School of Physics and Astronomy, University of Birmingham, United Kingdom.
Med Phys. 1998 Oct;25(10):1964-6. doi: 10.1118/1.598386.
This paper presents the results of an experimental investigation into the performance of the Birmingham accelerator-based epithermal BNCT beam. In-phantom gold foil activation and boron trifluoride tube measurements have been used. The results have been compared with calculated response rates using Monte Carlo modeling of the entire neutron system from source to phantom and detector. The excellent agreement obtained gives us confidence in the validity of the simulations and our ability to predict accurately the neutronic performance of our BNCT facility.
本文介绍了对基于伯明翰加速器的超热中子硼中子俘获治疗(BNCT)束性能进行实验研究的结果。采用了体模内金箔活化和三氟化硼管测量方法。已将结果与使用从源到体模及探测器的整个中子系统的蒙特卡罗建模计算出的响应率进行了比较。所获得的极佳一致性使我们对模拟的有效性以及准确预测我们的BNCT设施中子学性能的能力充满信心。