Suppr超能文献

Optimization of contrast dosage for gadolinium-enhanced 3D MRA of the pulmonary and renal arteries.

作者信息

Hany T F, Schmidt M, Hilfiker P R, Steiner P, Bachmann U, Debatin J F

机构信息

Department of Diagnostic Radiology, University Hospital Zurich, Zürich, Switzerland.

出版信息

Magn Reson Imaging. 1998 Oct;16(8):901-6. doi: 10.1016/s0730-725x(98)00012-5.

Abstract

To determine the minimal contrast dosage required for diagnostic contrast-enhanced three-dimensional (3D) magnetic resonance angiography (MRA) image quality of the pulmonary (PAs) or renal arteries (RAs). In 12 volunteers (10 females, 2 males; mean age 24 years) imaging was performed with 4 different dosages: 0.05, 0.1, 0.2 and 0.3 mmol/kg of body weight (BW) 0.5 M gadolinium (Gd) contrast agent. The PAs and RAs were evaluated separately each in groups of six volunteers. Qualitative and quantitative signal-to-noise ratio (SNR) image analysis was performed. For the PAs, the increases in signal-to-noise ratio were paralleled by increases in image quality ratings. For the PAs, with the use of 0.05 mmol/kg, only 50.3% of all segments were rated diagnostic, whereas with higher dosages the percentage rose to 89.2% for 0.1 mmol/kg, 98.2% for 0.2 mmol/kg. and 99.1% for 0.3 mmol/kg. For the RAs, 0.3 mmol/kg provided no significant increase in singal-to-noise ratio compared to 0.2 mmol/kg (p = 0.4). Only by a dosage of 0.2 and 0.3 mmol/kg, all evaluated segments were diagnostic evaluable. A dose of 0.2 mmol/kg is required for proper assessment of the RAs or PAs.