Sutra J F, Chartier C, Galtier P, Alvinerie M
Laboratoire de Pharmacologie-Toxicologie, INRA, Toulouse, France.
Analyst. 1998 Jul;123(7):1525-7. doi: 10.1039/a802093k.
A method is described for the determination of eprinomectin in plasma using high-performance liquid chromatography with fluorescence detection (excitation and emission wavelengths 355 and 465 nm, respectively). The fluorescent derivative was obtained by a condensation reaction with trifluoroacetic anhydride and N-methylimidazole. The method employs 1 ml plasma samples and gives linear calibration graphs (r = 0.999) over the concentration range studied (0.5-50 ng ml-1). Solid extraction using the benchmate procedure was used for sample preparation. This method permits the determination of eprinomectin at levels as low as 0.1 ng ml-1 and is suitable for the pharmacokinetic study of eprinomectin in animals.